Siemens Enhanced Imaging System

by Siemens Medical Solutions USA, Inc.

510(k) K041166

Siemens Enhanced Imaging System is a Class II device made by Siemens Medical Solutions USA, Inc., cleared under FDA 510(k) K041166 on 17 May 2004, active as of 22 Oct 2026. 10 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

12 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK041166 Date17 May 2004ClearedStatusActive

Official records

Recalls

12 recalls · FDA

    • Terminated Z-0061-2017 FDA Class II initiated 16 Aug 2013

    The detectors on the Symbia S and Symbia T camera systems are supported and moved horizontally and vertically by four linear bearing cars. There is a potential for the linear bearing car to fail allowing the ball bearings to fall out.

    • Terminated Z-1086-2015 FDA Class II initiated 23 Oct 2012

    There is a potential for the linear bearing car to fail allowing the ball bearings to fall out.

  • 2 recalls, same reason

    • Terminated Z-0583-2010 FDA Unclassified (pre-2012) initiated 11 Dec 2009
    • Terminated Z-0584-2010 FDA Unclassified (pre-2012) initiated 11 Dec 2009 on shared 510(k) K041166

    Some of the hand controllers of the Symbia S & T systems are missing a resistor switch, and the absence of the switch may lead to unintended system motion during camera set up activities.

  • 2 recalls, same reason

    • Terminated Z-1676-2009 FDA Unclassified (pre-2012) initiated 22 Apr 2009
    • Terminated Z-1677-2009 FDA Unclassified (pre-2012) initiated 22 Apr 2009

    The pinion gear could crack and cause the gantry to spin freely thereby damaging the Symbia S or T System and potentially injuring a patient during a scan.

  • 2 recalls, same reason

    • Terminated Z-1649-2009 FDA Unclassified (pre-2012) initiated 11 Mar 2009
    • Terminated Z-1648-2009 FDA Unclassified (pre-2012) initiated 11 Mar 2009

    Patient injury can occur when the patient is lying on the patient bed and the automatic collimator exchanger is undergoing a collimator change operation at the launch of an acquisition workflow. Detector motions required for this change can cause collision with the patient or pallet if it is in brain scan position, i.e. the patient or pallet is into the field of view.

  • 2 recalls, same reason

    • Terminated Z-0190-2009 FDA Unclassified (pre-2012) initiated 29 Sep 2008
    • Terminated Z-0189-2009 FDA Unclassified (pre-2012) initiated 29 Sep 2008

    The protective plastic cap over the CT gantry power switch on the Line Connection Box may come loose, exposing the energized electrical contacts within the switch, thereby causing an electric hazard.

  • 2 recalls, same reason

    • Terminated Z-0548-2007 FDA Unclassified (pre-2012) initiated 30 Jan 2007
    • Terminated Z-0549-2007 FDA Unclassified (pre-2012) initiated 30 Jan 2007 on shared 510(k) K041166

    Symbia systems, running on e.soft version 5.5 or earlier, could allow a fully-extended patient pallet to come into contact with the pinhole collimator, resulting in system damage.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

13 dated events

  1. Recall initiated FDA recalls Z-0190-2009
  2. Recall initiated FDA recalls Z-0189-2009
  3. Recall initiated FDA recalls Z-1649-2009
  4. Recall initiated FDA recalls Z-1648-2009
  5. Recall initiated FDA recalls Z-1676-2009
  6. Recall initiated FDA recalls Z-1677-2009
  7. Recall initiated FDA recalls Z-0583-2010
  8. Recall initiated FDA recalls Z-0584-2010
  9. Recall initiated FDA recalls Z-1086-2015
  10. Recall initiated FDA recalls Z-0061-2017

3 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
KPS
Device class
Class II
Regulation
21 CFR Part 892.1200
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code KPS (System, Tomography, Computed, Emission).

Other devices from Siemens Medical Solutions USA, Inc.

See all devices from Siemens Medical Solutions USA, Inc. →