# SIGNA Creator

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/signa-creator-signa-creator>
- Manufacturer: [GE Healthcare Tianjin Company Limited](https://devicerts.com/manufacturers/ge-healthcare-tianjin-company-limited) (China)
- Device class: Class IIa (EU MDR); Class II (US FDA)
- FDA product code: LNH
- EMDN: Z11050104 CLOSED MAGNET MRI SCANNERS WITH MAGNETIC FIELD LESS THAN OR EQUAL TO 2T
- GMDN: Full-body MRI system, superconducting magnet (37654)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 8406821BUG00303GZ · UDI-DI 00195278577238 · registered 2023-03-03 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 00195278577238 · listed 2022-12-09 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K143251 · decision 2015-02-04 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1242-2025 · Class II · ongoing · initiated 2025-01-31: For certain MR systems, a scan can be resumed following a Power Monitor trip when the "6-minute average SAR" is above the limit indicated on the "SAR Display". The user interface may incorrectly enable a scan to proceed earlier than intended. If resumed by the operator, such a scan can result in potential excessive tissue heating, especially if the patient is in contact with a conductive material or has an implant.
- Z-1239-2025 · Class II · ongoing · initiated 2025-01-31: For certain MR systems, a scan can be resumed following a Power Monitor trip when the "6-minute average SAR" is above the limit indicated on the "SAR Display". The user interface may incorrectly enable a scan to proceed earlier than intended. If resumed by the operator, such a scan can result in potential excessive tissue heating, especially if the patient is in contact with a conductive material or has an implant.
- Z-2473-2024 · Class II · ongoing · initiated 2024-06-14: GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.
- Z-2475-2024 · Class II · ongoing · initiated 2024-06-14: GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.
- Z-2472-2024 · Class II · ongoing · initiated 2024-06-14: GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.
- Z-2470-2024 · Class II · ongoing · initiated 2024-06-14: GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.
- Z-2476-2024 · Class II · ongoing · initiated 2024-06-14: GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.
- Z-0596-2022 · Class II · ongoing · initiated 2021-12-23: The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.
- Z-0597-2022 · Class II · ongoing · initiated 2021-12-23: The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.
- Z-0137-2022 · Class II · terminated · initiated 2021-08-26: Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images.
- Z-2058-2021 · Class II · ongoing · initiated 2021-06-04: GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed patient orientation on the system prior to running the initial 3-Plane Localizer Scan (See Figure 1 for reference to buttons.) Selecting and saving a patient orientation that does not match the patient's actual position may result in incorrectly annotated and/or flipped images.
- Z-2059-2021 · Class II · ongoing · initiated 2021-06-04: GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed patient orientation on the system prior to running the initial 3-Plane Localizer Scan (See Figure 1 for reference to buttons.) Selecting and saving a patient orientation that does not match the patient's actual position may result in incorrectly annotated and/or flipped images.
- Z-3026-2017 · Class II · terminated · initiated 2017-05-11: Possible incorrect wiring of the Uninterruptable Power Supply, which could contribute to a potential shock hazard.
- Z-2731-2016 · Class II · terminated · initiated 2016-08-31: GE Healthcare is conducting a recall dealing with an incorrect RF Power Monitor Function involving SIGNA CREATOR and SIGNA EXPLORER which could result in higher than expected thermal dose to the patient and higher than expected localized heating. There have been no failures of this type reported, and no injuries reported as a result of this issue.

## Identity

- Generic name: Full-body MRI system, superconducting magnet [FDA GUDID (AccessGUDID)]
- Model / reference: SIGNA Creator [EUDAMED, FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00195278577238 [EUDAMED, FDA GUDID (AccessGUDID)]; 00840682113786 [FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 8406821BUG00303GZ [EUDAMED]
- 510(k) Number: K143251 [FDA GUDID (AccessGUDID)]
- FDA product code: LNH [FDA GUDID (AccessGUDID)]
- EMDN code: Z11050104 [EUDAMED]
- GMDN term: Full-body MRI system, superconducting magnet (37654) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIa [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 892.1000 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: France [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: SIGNA Creator, GE Healthcare Tianjin Company Limited. deviCERTS medical device catalogue. https://devicerts.com/devices/signa-creator-signa-creator (data as of 2026-11-20).
- Data sources: [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-20
- JSON: <https://devicerts.com/devices/signa-creator-signa-creator.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/signa-creator-signa-creator
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.