SIGNA Pioneer

by GE Healthcare Japan Corporation

510(k) K143345

SIGNA Pioneer is a medical device (FDA Class II; FDA product code LNH, System, Nuclear Magnetic Resonance Imaging) made by GE Healthcare Japan Corporation, cleared under FDA 510(k) K143345 on 10 Jul 2015, active as of 22 Oct 2026. 6 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK143345 Date10 Jul 2015ClearedStatusActive

Official records

From the FDA record

Received by the FDA
21 Nov 2014
FDA decision
10 Jul 2015 (Substantially Equivalent)
FDA review time
231 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K143345 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

6 recalls · 3 ongoing · FDA

    • Ongoing Z-2460-2024 FDA Class II initiated 14 Jun 2024

    GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.

    • Ongoing Z-0592-2022 FDA Class II initiated 23 Dec 2021

    The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.

    • Ongoing Z-2054-2021 FDA Class II initiated 4 Jun 2021

    GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed patient orientation on the system prior to running the initial 3-Plane Localizer Scan (See Figure 1 for reference to buttons.) Selecting and saving a patient orientation that does not match the patient's actual position may result in incorrectly annotated and/or flipped images.

    • Terminated Z-0134-2022 FDA Class II initiated 26 Aug 2021

    Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images.

    • Terminated Z-0876-2020 FDA Class II initiated 23 Dec 2019

    It was identified that due to a potential installation workflow issue, the MR system date could be set incorrectly. The system's date and time setting are used to populate the DICOM header information on images. This could result is an inaccurate date recorded on the images.

    • Terminated Z-1347-2016 FDA Class II initiated 1 Mar 2016

    Ferrous material in the SIGNA Pioneer Table Control Box (TCB) could cause unexpected attraction to the MR system's high strength magnetic field during servicing activities. This could create a potential risk of serious injury to service personnel who attempt to inappropriately remove the TCB from the magnetic field. There have been no events reported as a result of this issue. Clinical scanni

Timeline

7 dated events

  1. Cleared FDA 510(k) K143345
  2. Recall initiated FDA recalls Z-1347-2016
  3. Recall initiated FDA recalls Z-0876-2020
  4. Recall initiated FDA recalls Z-2054-2021
  5. Recall initiated FDA recalls Z-0134-2022
  6. Recall initiated FDA recalls Z-0592-2022
  7. Recall initiated FDA recalls Z-2460-2024

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
LNH
Device class
Class II
Regulation
21 CFR Part 892.1000
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Devices cleared under K143345

5 devices · FDA GUDID

Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.

Devices cleared under K143345
UDI-DISize and differences
4265300
Hangwei GE Medical Systems Co., Ltd.
426530000840682106504 —No longer on the market
NA 3.0T AA
USA INSTRUMENTS, INC.
5555167 / 3.0T AA00840682108881 —On the market
NA SIGNA Pioneer
GE HEALTHCARE JAPAN CORPORATION
SIGNA Pioneer00840682104401 —No longer on the market
NA TDI HEAD NECK ARRAY
USA INSTRUMENTS, INC.
TDI HEAD NECK ARRAY00840682115858 —On the market
NA TDI POSTERIOR ARRAY
USA INSTRUMENTS, INC.
TDI POSTERIOR ARRAY00840682108867 —On the market

Similar devices

Other devices filed under FDA product code LNH (System, Nuclear Magnetic Resonance Imaging).

Other devices from GE Healthcare Japan Corporation

See all devices from GE Healthcare Japan Corporation →