Signia SIGLU60A
by Covidien LP
Signia SIGLU60A is a Class II device made by Covidien LP, cleared under FDA 510(k) K160176 on 26 Apr 2016 and listed in FDA GUDID since 26 May 2017 (UDI-DI 10884521543508), active as of 23 Oct 2026. 14 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
13 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10884521543508 | Date26 May 2017 | StatusListed |
| United States | FDA 510(k)SESE | NumberK160176 | Date26 Apr 2016 | StatusActive |
Official records
- AccessGUDID record 10884521543508
- FDA 510(k) database K160176
Across registries
- FDA 510(k) K160176 decided 26 Apr 2016 Active
- FDA GUDID UDI-DI 10884521543508 listed 26 May 2017 Listed
Recalls
-
- Ongoing Z-1228-2023
Affected lots have the potential for a broken sled vane, which may cause the reload to misfire leading to non-functional staple line closure, transecting tissue without forming staples, and tissue hang-up. These conditions may be associated to a delay to treatment, unspecified infection, hemorrhage/blood loss/bleeding, failure to anastomose, peritonitis, sepsis, pneumothorax, tissue trauma, or death.
-
- Ongoing Z-1834-2019
- Ongoing Z-1828-2019
- Ongoing Z-1826-2019
- Ongoing Z-1832-2019
- Ongoing Z-1827-2019
- Ongoing Z-1836-2019
- Ongoing Z-1833-2019
- Ongoing Z-1835-2019
- Ongoing Z-1830-2019
- Ongoing Z-1825-2019
- Ongoing Z-1829-2019
- Ongoing Z-1831-2019
The device may be missing one of two pin components that maintain alignment of the device jaws, resulting in incomplete staple formation which may lead to bleeding, anastomotic leak, peritonitis, or pneumothorax which can result in the potential for infection and/or sepsis.
-
- Terminated Z-1237-2018
Product reportedly shutting down during use.
Timeline
- Recall initiated FDA recalls Z-1832-2019
- Recall initiated FDA recalls Z-1827-2019
- Recall initiated FDA recalls Z-1836-2019
- Recall initiated FDA recalls Z-1833-2019
- Recall initiated FDA recalls Z-1835-2019
- Recall initiated FDA recalls Z-1830-2019
- Recall initiated FDA recalls Z-1825-2019
- Recall initiated FDA recalls Z-1829-2019
- Recall initiated FDA recalls Z-1831-2019
- Recall initiated FDA recalls Z-1228-2023
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Signia
- Generic name
- Endoscopic manual linear cutting stapler, single-use
- Model / reference
- SIGLU60A
- Primary DI / UDI-DI
- 10884521543508
- 510(k) Number
- FDA product code
- GDW
- GMDN term
- Endoscopic manual linear cutting stapler, single-use
- Device class
- Class II
- Regulation number
- 878.4750
- GUDID distribution status
- In Commercial Distribution
- Size
- Length — 60 Millimeter
Similar devices in this category