Skip to content

Single set 1l 077.0715

by Medela AG

Part of a family of 10 devices: see the family page

Ref 077.0715

Single set 1l 077.0715 is a surgical suction system collection container (EU MDR Class I; FDA Class II) made by Medela AG, registered in EUDAMED on 30 Jun 2026 (Basic UDI-DI 07612367rzcxwfVV), cleared under FDA 510(k) K170329 on 24 Mar 2017 (3 earlier submissions) and listed in FDA GUDID since 31 May 2024 (UDI-DI 07612367011372), active as of 12 Nov 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number07612367rzcxwfVV Basic UDI-DI 07612367011372UDI-DIDate30 Jun 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number07612367011372 UDI-DI Date31 May 2024ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK170329 Date24 Mar 2017DecidedStatusActive

Official records

From the FDA record

Device description
Single set 1l
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 07612367rzcxwfVV registered 30 Jun 2026 Active
  • FDA 510(k) K170329 decided 24 Mar 2017 Active· +3 more in the status table
  • FDA GUDID UDI-DI 07612367011372 listed 31 May 2024 Listed

Recalls

1 recall · FDA

    • Terminated Z-1502-2021 FDA Class II initiated 2 Dec 2020

    Incorrect expiration date of "2023-07-24" on label of sterile tubing. Correct expiration date should be "2021-07-24".

Timeline

7 dated events

  1. Cleared FDA 510(k) K130123
  2. Cleared FDA 510(k) K150134
  3. Cleared FDA 510(k) K153663
  4. Cleared FDA 510(k) K170329
  5. Recall initiated FDA recalls Z-1502-2021
  6. Listed FDA GUDID 07612367011372
  7. Registered EUDAMED 07612367rzcxwfVV

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Single set 1l
Generic name
Surgical suction system collection container, reusable
Device name
Reusable Collection System Sets
Model / reference
077.0715
Primary DI / UDI-DI
07612367011372
Basic UDI-DI
07612367rzcxwfVV
FDA product code
BTA, HDB, MUU, QPB
EMDN code
A060399 Fluid collection bags and systems - other
GMDN term
Surgical suction system collection container, reusable
Device class
Class I EUDAMED
Class II GUDID
Regulation number
878.4780, 884.4340, 878.5040
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under FLUID COLLECTION BAGS AND SYSTEMS - OTHER.

Other devices from Medela AG

See all devices from Medela AG →

Properties

  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (22, all answered No)