Skip to content

Skintact Multifunctional Electrodes with DH02 Gel with Different Connectors Compatible with Different Defibrillators

by Leonhard Lang GmbH

510(k) K072233

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

2 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK072233 Date5 Oct 2007ClearedStatusActive

Recalls

2 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-2234-2009 FDA Unclassified (pre-2012) initiated 10 Jul 2009
    • Terminated Z-2233-2009 FDA Unclassified (pre-2012) initiated 10 Jul 2009

    A potential risk was identified associated with the connectors of the defibrillation electrodes DF20. It was found that some of the connectors do not slip easily into the sockets of the defibrillator or an extension cord of the defibrillator. In such cases increased force or some wiggling is required to insert the connector fully. A potential risk for patients exist, if (a) such a connector (b)

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
MKJ
Device Class
Class III
Regulation
21 CFR Part 870.5310
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Skintact Multifunctional Electrodes are adhesive electrodes designed for use with automated external defibrillators (non-wearable). These electrodes facilitate cardiac monitoring and defibrillation by delivering electrical impulses to the chest during emergencies, enabling resuscitation efforts in out-of-hospital cardiac arrest scenarios.

These electrodes are supplied as single-use, pre-gelled (with DH02 gel) adhesive pads featuring multiple connector types to ensure compatibility with a range of defibrillator models. They are classified as Class III medical devices under FDA regulations (870.5310) and have received FDA 510(k) clearance (K072233) as substantially equivalent to the predicate device. Storage and handling follow standard single-use medical device protocols, with no MRI safety considerations specified.

Other devices from Leonhard Lang GmbH

See all devices from Leonhard Lang GmbH →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Are these electrodes reusable or intended for single-use only, and how should they be handled after use?

    The Skintact Multifunctional Electrodes are designed for single-use only. Since they are pre-gelled with DH02 gel and adhesive, they should be discarded after a single application to maintain sterility and ensure safe, reliable performance. Proper disposal follows standard single-use medical device protocols, as no reuse is recommended or supported by the manufacturer.

  • What types of defibrillators are these electrodes compatible with, and how do I confirm compatibility with my specific device?

    These electrodes are engineered to work with multiple automated external defibrillators (non-wearable) and include multiple connector types to ensure broad compatibility. The listed FDA registration numbers (e.g., 3026976873, 1218058, etc.) correspond to defibrillator models they are cleared for. To confirm compatibility with your device, cross-reference your defibrillator’s model number against the provided registration numbers or consult Leonhard Lang GmbH’s documentation.

  • How should I store these electrodes, and are there any special handling instructions before use?

    The electrodes should be stored following standard single-use medical device protocols, which typically include keeping them in a clean, dry environment away from direct sunlight or extreme temperatures. Since they are pre-gelled and adhesive, ensure the packaging remains intact until use to preserve sterility and functionality. No MRI safety considerations are specified, so standard storage practices apply.

  • What sizes or models of these electrodes are available, and how do I determine the correct size for a patient?

    The provided data does not specify exact sizes or model variants of the Skintact electrodes beyond their multifunctional design. However, they are designed for adult chest application in out-of-hospital cardiac arrest scenarios. Sizing is typically determined by the defibrillator’s electrode placement guidelines, which may vary by manufacturer. For precise sizing guidance, refer to the defibrillator’s user manual or consult Leonhard Lang GmbH’s support resources.