Skip to content

Smart Pressure Controller PC1Q

by Edwards Lifesciences LLC

Ref PC1Q

Smart Pressure Controller PC1Q is a general-purpose multi-parameter bedside monitor (EU MDR Class IIb; FDA Class II) made by Edwards Lifesciences LLC, registered in EUDAMED on 1 Oct 2026 (Basic UDI-DI 0690103D001HNI000T4), cleared under FDA 510(k) K243781 on 23 Jul 2025 and listed in FDA GUDID since 10 Sep 2025 (UDI-DI 00690103219395), active as of 24 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K243781

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0690103D001HNI000T4 Basic UDI-DI 00690103219395UDI-DIDate1 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00690103219395 UDI-DI Date10 Sep 2025ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK243781 Date23 Jul 2025DecidedStatusActive

Official records

From the FDA record

Device description
SMART PRESSURE CONTROLLER
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0690103D001HNI000T4 registered 1 Oct 2026 Active
  • FDA 510(k) K243781 decided 23 Jul 2025 Active
  • FDA GUDID UDI-DI 00690103219395 listed 10 Sep 2025 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-3250-2026 FDA Class II initiated 11 Aug 2026

    Due to incorrect switching of Channel 1 and 2 on the module and flag labels on the tissue oximetry cables.

Timeline

4 dated events

  1. Cleared FDA 510(k) K243781
  2. Listed FDA GUDID 00690103219395
  3. Recall initiated FDA recalls Z-3250-2026
  4. Registered EUDAMED 0690103D001HNI000T4

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Smart Pressure Controller
Generic name
General-purpose multi-parameter bedside monitor
Device name
HemoSphere Non-Invasive
Model / Ref / Catalog
PC1Q
Primary DI / UDI-DI
00690103219395
Basic UDI-DI
0690103D001HNI000T4
510(k) Number
FDA product code
DQK, DQE, QAQ, MUD, DXN, DSB, FLL, QMS, OLW
EMDN code
Z1203020280 Multi-parameter monitors - hardware accessories
GMDN term
General-purpose multi-parameter bedside monitor
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
870.1425, 870.1230, 870.2210, 870.2700, 870.1130, 870.2770, 880.2910, 870.5600, 882.1400
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under MULTI-PARAMETER MONITORS - HARDWARE ACCESSORIES.

Other devices from Edwards Lifesciences LLC

See all devices from Edwards Lifesciences LLC →

Properties

  • Single use
  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (21, all answered No)