# SmartDrive® MX2+

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/smartdrive-r-mx2-e08fe4df>
- Manufacturer: [Max Mobility, LLC](https://devicerts.com/manufacturers/max-mobility-llc) (United States)
- Device class: Class I (EU MDR); Class II (US FDA)
- FDA product code: ITI
- EMDN: Y122410 ELECTRIC PROPULSION UNIT
- GMDN: Wheelchair electric-motor-driven propulsion system (42805)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 08618960003SDMX237 · UDI-DI 00861896000310 · registered 2026-10-08 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 00861896000310 · listed 2017-01-16 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K151199 · decision 2015-07-30 · decision SESE · status: Active · from GUDID

## Recalls

- Z-2538-2025 · Class I · ongoing · initiated 2025-08-12: Due to a faulty electrical connection between the speed control Dial and the wheelchair motor, their is a potential for lost of control of the device potentially resulting in minor or major injuries.
- Z-2539-2025 · Class I · ongoing · initiated 2025-08-12: Due to a faulty electrical connection between the speed control Dial and the wheelchair motor, their is a potential for lost of control of the device potentially resulting in minor or major injuries.
- Z-2540-2025 · Class I · ongoing · initiated 2025-08-12: Due to a faulty electrical connection between the speed control Dial and the wheelchair motor, their is a potential for lost of control of the device potentially resulting in minor or major injuries.
- Z-1116-2025 · Class I · ongoing · initiated 2024-12-20: Due to faulty circuit board in speed control remote use in conjunction with a wheelchair power assist, their is a potential for lost of control of device potentially resulting in minor and major injuries.
- Z-1117-2025 · Class I · ongoing · initiated 2024-12-20: Due to faulty circuit board in speed control remote use in conjunction with a wheelchair power assist, their is a potential for lost of control of device potentially resulting in minor and major injuries.
- Z-2004-2023 · Class II · ongoing · initiated 2023-05-10: When multiple processes are running on the watch's Central Processing Unit (CPU), the application may fail unexpectedly. If this happens, the motor on the power assist device continues to run and the user may not be able to stop the device using tap gestures.
- Z-2005-2023 · Class II · ongoing · initiated 2023-05-10: When multiple processes are running on the watch's Central Processing Unit (CPU), the application may fail unexpectedly. If this happens, the motor on the power assist device continues to run and the user may not be able to stop the device using tap gestures.

## Identity

- Trade name: SmartDrive MX2+ [EUDAMED]; SmartDrive® [FDA GUDID (AccessGUDID)]
- Generic name: Wheelchair electric-motor-driven propulsion system [FDA GUDID (AccessGUDID)]
- Device name: MX2+ [EUDAMED]
- Model / reference: MX2+ [EUDAMED, FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00861896000310 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 08618960003SDMX237 [EUDAMED]
- 510(k) Number: K151199 [FDA GUDID (AccessGUDID)]
- FDA product code: ITI [FDA GUDID (AccessGUDID)]
- EMDN code: Y122410 [EUDAMED]
- GMDN term: Wheelchair electric-motor-driven propulsion system (42805) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class I [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 890.3860 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Malta [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Over-the-counter: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Prescription use: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: SmartDrive® MX2+, Max Mobility, LLC. deviCERTS medical device catalogue. https://devicerts.com/devices/smartdrive-r-mx2-e08fe4df (data as of 2026-11-23).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-23
- JSON: <https://devicerts.com/devices/smartdrive-r-mx2-e08fe4df.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.