SMR Shoulder 9013.75.142
Part of a family of 25 devices: see the family page
Ref 9013.75.142Model 80333902A060BS, SMR Shoulder - Reverse Liner Pusher
SMR Shoulder 9013.75.142 is an orthopaedic implant impactor (EU MDD Class IIa; EU MDD Class I; FDA Class II) made by Limacorporate, registered in EUDAMED on 29 Oct 2026 (Basic UDI-DI 80333902A060BS), cleared under FDA 510(k) K100858 on 10 Dec 2010 and listed in FDA GUDID since 27 Nov 2021 (UDI-DI 08033390199087), active as of 7 Nov 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | Number80333902A060BS 08033390199087 | Date29 Oct 2026 | StatusActive |
| European Union | CE/MDR EUDAMED | Number80333902A060BS 08033390199087 | Date29 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number08033390199087 | Date27 Nov 2021 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK100858 | Date10 Dec 2010 | StatusActive |
Official records
- EUDAMED public site 80333902A060BS
- AccessGUDID record 08033390199087
- FDA 510(k) database K100858
From the FDA record
- Device description
- SMR Shoulder - Reverse Liner Pusher
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 80333902A060BS registered 29 Oct 2026 Active
- FDA 510(k) K100858 decided 10 Dec 2010 Active
- FDA GUDID UDI-DI 08033390199087 listed 27 Nov 2021 Listed
Recalls
-
- Terminated Z-2539-2015
- Terminated Z-2540-2015
The dimensions of the mating features of the recalled products are out of specification causing the device to be difficult to assemble.
Timeline
- Cleared FDA 510(k) K100858
- Recall initiated FDA recalls Z-2539-2015
- Recall initiated FDA recalls Z-2540-2015
- Listed FDA GUDID 08033390199087
- Registered EUDAMED 80333902A060BS
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- SMR Shoulder - Reverse Liner Pusher EUDAMEDSMR Shoulder GUDID
- Generic name
- Orthopaedic implant impactor, reusable
- Model / Ref / Catalog
- 9013.75.142, 80333902A060BS, SMR Shoulder - Reverse Liner Pusher
- Primary DI / UDI-DI
- 08033390199087
- Basic UDI-DI
- 80333902A060BS, B-08033390199087
- 510(k) Number
- FDA product code
- KWT, HSD
- EMDN code
- L091104 Orthopaedic prostheses positioners, reusable
- GMDN term
- Orthopaedic implant impactor, reusable
- Device class
- Class IIa EUDAMEDClass I EUDAMEDClass II GUDID
- Regulation number
- 888.3650, 888.3690
- EU registration type
- Standard deviceLegacy device (under a directive)
- EU market of registration
- Italy
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa Class I | Class II |
Similar devices in this category
Other devices filed under ORTHOPAEDIC PROSTHESES POSITIONERS, REUSABLE.
- G7® 010002466 by Biomet Orthopedics, Inc.
- Persona® 42-5891-005-30 by Zimmer, Inc.
- Drill/Tap Sleeve C22005 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- G7® 110017262 by Biomet Orthopedics, Inc.
- Coupling Screw C06015 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- 00-5853-074-15 by Zimmer, Inc.
- Aequalis Reversed II MWF715 by TORNIER, INC.
- Tornier Latitude 9030434 by TORNIER, INC.
- GLOBAL UNITE 2100-01-040 by DePuy Ireland UC