Snowden-Pencer 89-6212
Snowden-Pencer 89-6212 (896212) is a hand-held endoscopic retractor (FDA Class II; FDA product code GCJ, Laparoscope, general & plastic surgery) made by Steris Corporation, cleared under FDA 510(k) K092684 on 22 Jan 2010 and listed in FDA GUDID since 23 Sep 2016 (UDI-DI 10885403122873), active as of 23 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10885403122873 | Date23 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK092684 | Date22 Jan 2010 | StatusActive |
Official records
- AccessGUDID record 10885403122873
- FDA 510(k) database K092684
From the FDA record
- Device description
- Snowden-Pencer MIS DIAMOND-FLEX TRIANGULAR RETRACTOR, ANGLED, 80MM 5MM, 45CM
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K092684 decided 22 Jan 2010 Active
- FDA GUDID UDI-DI 10885403122873 listed 23 Sep 2016 Listed
Recalls
-
- Terminated Z-2212-2016
BD, formerly CareFusion, has identified a potential risk associated with a weld failure which could result in the wire protruding thru the tip of the instrument when articulated. If this failure were to occur while in use in a procedure it has the potential to damages tissue or organs
Timeline
- Cleared FDA 510(k) K092684
- Recall initiated FDA recalls Z-2212-2016
- Listed FDA GUDID 10885403122873
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Snowden-Pencer
- Generic name
- Hand-held endoscopic retractor, reusable
- Model / Ref / Catalog
- 89-6212, 896212
- Primary DI / UDI-DI
- 10885403122873
- 510(k) Number
- FDA product code
- GCJ
- GMDN term
- Hand-held endoscopic retractor, reusable
- Device class
- Class II
- Regulation number
- 876.1500
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices
Other devices filed under FDA product code GCJ (Laparoscope, general & plastic surgery).
- Endo Bag 25040 by Covidien LP
- SCANLAN® 9338-10 by SCANLAN INTERNATIONAL INC
- Surgical Retractor by Advanced Surgical, Inc.
- Roth Net 00711162 by US Endoscopy
- Olympus WA64160L by Olympus Winter & Ibe GmbH
- SCISSORS, GRASPERS, FORCEPS by American Cyanamid Co.
- Integra® MicroFrance® CEV992 by Integra Microfrance
- ERAGON MODULAR 8393184 8393.184 by Richard Wolf GmbH
- DAVOL LAPAROSCOPIC INSUFFLATION NEEDLE FOR GENERAL LAPAROSCOPIC PROCEDURES by Davol Inc., Sub. C. R. Bard, Inc.
- ERAGON MODULAR 83932827 by Richard Wolf GmbH