Skip to content

SoftTouch Guide Catheter

by Mallinckrodt Medical

510(k) K934685

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK934685 Date7 Apr 1994ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DQY
Device Class
Class II
Regulation
21 CFR Part 870.1250
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The SoftTouch Guide Catheter is a percutaneous catheter classified under product code DQY, designed as a flexible tubular device for intravascular navigation. It serves as a conduit within blood vessels, facilitating the passage of other interventional tools such as guidewires, stents, or balloons during cardiovascular procedures. Its construction prioritises atraumatic insertion and stability within arterial or venous pathways, reducing trauma to vessel walls. The device is intended for use in diagnostic and therapeutic cardiovascular interventions requiring precise catheter placement.

This catheter is supplied as a single-use, sterile medical device, intended for percutaneous insertion via a dilator or introducer sheath. It is regulated under FDA 510(k) clearance (K934685) and falls under the Cardiovascular Device Advisory Committee classification. The device is not MRI-safe, and its dimensions are not specified in the available data. Storage conditions require protection from contamination and physical damage, adhering to standard sterile medical device protocols. No additional regulatory approvals beyond the 510(k) clearance are mentioned.

Other devices from Mallinckrodt Medical

See all devices from Mallinckrodt Medical →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the SoftTouch Guide Catheter used for?

    The SoftTouch Guide Catheter is designed as a flexible tubular device for intravascular navigation. It acts as a conduit within blood vessels to guide other interventional tools—such as guidewires, stents, or balloons—during diagnostic and therapeutic cardiovascular procedures. Its atraumatic design minimizes trauma to vessel walls, ensuring stability during precise catheter placement.

  • Is the SoftTouch Guide Catheter single-use or reusable?

    The SoftTouch Guide Catheter is supplied as a single-use device. This design choice ensures sterility and reduces the risk of contamination or cross-infection between patients, adhering to standard medical device protocols for sterile use.

  • How is the SoftTouch Guide Catheter supplied and prepared for use?

    The catheter is supplied sterile and intended for percutaneous insertion via a dilator or introducer sheath. Before use, it must be handled under sterile conditions to prevent contamination. Follow standard sterile medical device protocols for preparation, including checking for physical damage and ensuring proper storage.

  • What storage conditions are required for the SoftTouch Guide Catheter?

    The device must be stored in a clean, dry environment protected from contamination and physical damage. Since it is single-use and sterile, it should remain in its original packaging until immediately before use. Avoid exposure to extreme temperatures or moisture, which could compromise sterility or integrity.

  • Can the SoftTouch Guide Catheter be used with MRI equipment?

    The SoftTouch Guide Catheter is explicitly not MRI-safe. If MRI imaging is required during or after its use, alternative imaging modalities should be considered to avoid potential risks associated with MRI exposure.