Solitaire FR Revascularization Device
by Micro Therapeutics Dba Ev3 Neurovascular
510(k) K113455
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK113455 | Date2 Mar 2012 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- NRY
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.1250
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 26 Sep 2026
The Solitaire FR Revascularization Device is a catheter-based thrombus retriever designed for use in the cardiovascular system. It consists of a nitinol scaffolding design attached to a pushwire and is intended to be delivered through a micro catheter, deployed across a clot, and removed along with the clot to enable revascularization of an occluded intracranial vessel.
The device is supplied as a single-use, sterile product and is intended for use in neurovascular procedures. It received FDA 510(k) clearance (K113455) on March 2, 2012, and is classified as a Class II device under regulation 870.1250 with product code NRY. No information regarding MRI safety, specific sizes, or storage conditions is provided in the source data.
Other devices from Micro Therapeutics, Inc. d/b/a ev3 Neurovascular
See all devices from Micro Therapeutics, Inc. d/b/a ev3 Neurovascular →
Questions
AI-generated answers, 26 Sep 2026
What is the Solitaire FR Revascularization Device used for?
The Solitaire FR Revascularization Device is a catheter-based thrombus retriever designed for use in the cardiovascular system. It is intended to be delivered through a micro catheter, deployed across a clot in an occluded intracranial vessel, and removed along with the clot to enable revascularization.
Is the Solitaire FR Revascularization Device sterile and single-use?
Yes, the device is supplied as a single-use, sterile product. This means it is intended for one patient only and must not be reprocessed or reused, ensuring patient safety and reducing infection risk in neurovascular procedures.
What regulatory pathway was used for the Solitaire FR Revascularization Device?
The device received FDA 510(k) clearance under submission K113455 on March 2, 2012. It was found substantially equivalent to a predicate device and is classified as a Class II medical device under regulation 870.1250 with product code NRY.