- Terminated Z-0771-2021
System does not trigger a cancel command followed by a reload of the scan with the new parameter(s). This issue may result in a delay in diagnosis and/or need for patient rescan
-
- Terminated Z-3025-2020
Sporadic problems with the current software may result in scanning workflow interruptions and unexpected user notifications causing delay in diagnosis or patient rescan
-
- Terminated Z-0406-2020
Software issue identified in the software versions syngo CT VB20 running on the SOMATOM CT Scanner: scan aborts and system crashes
-
- Terminated Z-2274-2019
Potential for four safety-related software issues impacting systems utilizing syngo.CT software version VB10A which may result in a scan abort.
-
- Terminated Z-0692-2017
Siemens is providing software update version VA50A_SP3 to address the software bugs that were identified through normal field monitoring and the Global Complaint Handling Process. Correction for the problems are as follows: 1. Correction to volumetric misrepresentations of high contrast objects when using ADMIRE. 2. Correction to highly sporadic scan aborts due to temporarily tube currents at 0mA. 3. Correction to missing Microsoft Hotfixes (MS16-001, MS15-135, MS15-088, MS15-048). 4. Correction to highly sporadic image artifacts caused by error signals from high voltage chain at extremely high tube currents. 5. Correction to highly sporadic incomplete image reconstruction due to temporary slow hard disk write speed. 6. Correction to highly sporadic scan aborts due to temporarily high disk load of system disk. 7. Correction to highly sporadic image artifacts generated by scatter correction in case of tube arcings.
-
- Terminated Z-1558-2016
The Neonate Head protocol with the pediatric kernel Hp38 could result in artefacts and possibly lead to a misdiagnosis (i.e. either non-existing blood or liquid is mimicked in the images or actual existing blood or liquid is not depicted as expected). There is also a risk of a potential misdiagnosis in using this protocol for surgery planning. Investigations revealed an incorrect parameterization of the reconstruction algorithm applied for the pediatric head kernel as cause of the problem.
-
- Terminated Z-0107-2016
Software and firmware bugs
-
- Terminated Z-1267-2015
Possibility of image artifacts during data acquisition when using Adaptive Cardio Sequence, Turbo Flash, and Head modes. The update improves system start-up behavior and resuming, ECG handling with visual feedback of correct placement of ECG leads and contact quality, and other safety related issues.
-
- Terminated Z-0971-2015
Artifacts are found in acquired imaging on the SOMATOM Force.
Timeline
- Cleared FDA 510(k) K133589
- Recall initiated FDA recalls Z-0971-2015
- Recall initiated FDA recalls Z-1267-2015
- Recall initiated FDA recalls Z-0107-2016
- Recall initiated FDA recalls Z-1558-2016
- Recall initiated FDA recalls Z-0692-2017
- Recall initiated FDA recalls Z-2274-2019
- Recall initiated FDA recalls Z-0406-2020
- Recall initiated FDA recalls Z-3025-2020
- Recall initiated FDA recalls Z-0771-2021
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- JAK
- Device class
- Class II
- Regulation
- 21 CFR Part 892.1750
- Advisory committee
- Radiology
- FDA decision
- SESE Substantially Equivalent
Devices cleared under K133589
Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.
| UDI-DI | Size and differences | |||
|---|---|---|---|---|
| Somatom Force 10742326 | 10742326 | 04056869006956 | — | On the market |
Similar devices
Other devices filed under FDA product code JAK (System, X-Ray, Tomography, Computed).
- SYNGO.CT NEURO PERFUSION by Siemens Medical Systems USA, Inc.
- AQUILION ONE VISION, V4.90 by Toshiba America Medical Systems, In.C
- EXEL 2002 & 2002FS CT SCANNER by Elscint, Inc.
- PERCUNAV by Philips Health Care
- IG 4 IMAGE GUIDED SYSTEM by VERAN MEDICAL TECHNOLOGIES INC.
- SMART BREATH RESPIRATORY COMPENSATION OPTION by GE MEDICAL SYSTEMS, INC.
- RTR-2000/RTR-4000 by Terarecon Inc.
- OMNIMEDICAL 400L by Omnimedical Services, Inc.
- MODEL TSX-301B AQUILION CT SYSTEM by Toshiba America Medical Systems, In.C
- SYNERVIEW MODEL 6545 by Philips Medical Systems (Cleveland), Inc.