Spectral CT on Rails
by Philips Medical Systems Nederland B.V. Netherlands EUDAMED510(k)GUDID
Ref 728334
Product code JAKEMDN Z11030601
Regulatory status
Recall ongoing. 13 ongoing FDA recalls. See recalls
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0884838BM996UE | Date13 Jul 2025 | StatusActive |
| United States | GUDID listing GUDID | Number00884838103627 | Date13 Jul 2022 | StatusIn distribution |
| United States | FDA 510(k) 510(k) | NumberK212875 | Date13 May 2022 | StatusActive |
Coverage
- Active
- Not covered
- United States
- European Union
Recalls
-
- Ongoing Z-1825-2026
Philips has identified three software issues: 1. During a continuous CT (CCT) scan, there is the potential that the Gantry could remain at the current scan position after pressing Go. 2. Potential where the message of Previous Surview Exists Select Previous Surview? or should display but does not appear. 3. After performing Surview and planning the Brain Helical acquisition by setting Brain Area DoseRight Index to increase the dose, there is the potential that the Define Head Area option in the context menu is grayed out.
-
- Ongoing Z-1318-2026
As part of the CT systems sub assembly, thirty-two (32) fasteners are used to attach the rotor to the bearing within the gantry. One or more of these fasteners may not be torqued to specification. If multiple fasteners are not torqued to specification, the rotor or rotor parts may become unsecured or displaced. While there has been no reported or observed event of expelled parts during gantry rotation, unsecured rotor parts may potentially be expelled.
-
- Ongoing Z-2034-2025
Devices with affected software may experience two unintended motion issues that may lead to contact between the Gantry or table with the operator or patient, along with additional software issues that affect CT performance.
-
- Ongoing Z-1324-2025
Multiple problems identified with the software version leading to various scanning and image issues, and unintended device movement.
-
- Ongoing Z-0583-2025
Potential for a plan box not updated issue during Interventional procedure with Spectral CT that may lead to a collision with the operator or with the needle placed inside the patient, and an incorrect patient ID software issue that may lead to misdiagnosis.
-
- Ongoing Z-1756-2024
Potential for third party oncology marking laser to be reflected off the gantry cover surface, which can potentially lead to misdiagnosis and subsequent incorrect treatment.
-
- Ongoing Z-1054-2024
- Ongoing Z-1055-2024
A software issue that can incorrectly label all captured images that may lead to misdiagnosis and subsequent incorrect treatment.
-
- Ongoing Z-0725-2024
Multiple software issues that affect device functionality.
-
- Ongoing Z-0319-2024
This recall is part of a 2-issue recall for the same system. When using the IVC needle position button, on the IVC control box during a series of scans, the plan box may not move to the desired needle position. This issue could result in the gantry moving to a location the operator does not expect. If this occurs, it presents a risk that the scan could occur at an incorrect location, or that the unintended motion of the gantry could cause a collision with the user or needle. The other part of the recall involves a software crash when the CCT foot pedal is activated (as described in RES ID93363).
-
- Ongoing Z-0306-2024
When preparing for CCT Fluoroscopy mode and activating the CCT foot pedal simultaneously, the operator may experience a software crash. This would result in the system needing to be restarted.
-
- Ongoing Z-1584-2023
Pressing the Unload Pedal of the foot switch to perform the unload function may cause entrapment of the operators foot. If foot or leg entrapment occurs while pressing Unload Pedal, the risk to operators may include: pain, muscle or ligament sprain, abrasion, laceration, contusion, fracture, loss of function, and joint dislocation.
-
- Ongoing Z-1986-2021
Significant wear of the Monitor Bracket Assembly shaft goes unrecognized could potentially lead to the Monitor Bracket Assembly detaching from the Suspension Arm and result in potential hazard for the monitor to fall while remaining attached to the cables resulting in patient, operator, bystander, or service person to serious injury.
-
- Terminated Z-2318-2021
When setting patient weight unit preferences to pounds, SynchRight P3T (Personalized Patient Protocol) software will result in increased contrast volume, resulting in increased contrast volume recommended for the patient.
Specification
- Generic Name
- Full-body CT system
- Device Name
- Spectral CT on Rails system
- Model / Ref / Catalog
- 728334, Spectral CT on Rails
- Primary DI / UDI-DI
- 00884838103627
- Basic UDI-DI
- 0884838BM996UE
- FDA Product Code
- JAK
- EMDN Code
- Z11030601 Computed tomographs - not exceeding 2 layers
- GMDN Term
- Full-body CT system
- Device Class
- Class IIb EUDAMEDClass II GUDID
- Regulation Number
- 892.1750
- Market of Registration
- Netherlands
- Commercial Distribution
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / Reference | 728334 | Spectral CT on Rails |
| Device Class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- NL-MF-000001489
Other devices from Philips Medical Systems Nederland B.V.
See all devices from Philips Medical Systems Nederland B.V. →
Properties & raw data
Show properties, registry sources and raw records
Other properties (21)
- Sterile: No
- Single Use: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Lot / Batch Number: No
- Expiration Date: No
- Manufacturing Date: No
Sources (3)
- EUDAMED 63ac02df-a455-478c-bf10-3cf6617d578a
- FDA UDI 8d4c5f9f-b95f-4083-828f-a21aec12aed0
- FDA 510(k) K203020