Specular Microscope Cem-530
Ref B01E008Model CEM-530
Specular Microscope Cem-530 (B01E008) is an ophthalmic specular microscope (EU MDR Class IIa; FDA Class II; FDA product code NQE, Microscope, Specular) made by Nidek Co., Ltd., registered in EUDAMED on 21 May 2024 (Basic UDI-DI 4987669211G5) with CE/MDR certificate 4202074CE01 (expired), cleared under FDA 510(k) K173980 on 14 Mar 2018 (2 earlier submissions) and listed in FDA GUDID since 26 Aug 2016 (UDI-DI 04987669100530), expired (EUDAMED), active (FDA 510(k)) as of 24 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number4202074CE01 | Date30 Jun 2026 | StatusExpired |
| United States | FDA 510(k) 510(k) | NumberK173980 | Date14 Mar 2018 | StatusActive |
| United States | GUDID listing GUDID | Number04987669100530 | Date26 Aug 2016 | StatusListed |
Official records
- EUDAMED public site 4987669211G5
- AccessGUDID record 04987669100530
- FDA 510(k) database K173980
- FDA 510(k) database K151706
- FDA 510(k) database K130565
From the FDA record
- Device description
- The NIDEK Specular Microscope CEM-530 provides non-contact, high magnification image capture of endothelium enabling observation of the size and shape of cells. Information such as the number of endothelial cells, cell density, and cell area is analyzed through the captured images. The captured images and analysis results of endothelium are used for intraocular or corneal surgery, postoperative follow-up, and corneal observation such as for endothelial disorders or the corneal state of patients who wear extended-wear contact lenses. Observation is possible in the central area (visual angle: 5°) and peripheral area (visual angle: 27°) using a periphery capture function as well as in the center of the cornea. The captured images and analysis results can be printed on the built-in printer or optional video printer, or output to an external device over LAN connection.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 4987669211G5 registered 21 May 2024 Expired
- FDA 510(k) K173980 decided 14 Mar 2018 Active
- FDA GUDID UDI-DI 04987669100530 listed 26 Aug 2016 Listed
Certificates
- 4202074CE01 Expired
Quality management system EU MDR
- Certifier
- DEKRA Certification B.V. 0344
- Issued
- 30 Jun 2026
- Expires
- 1 Nov 2026
- Reason
- Add device or group
Recalls
-
- Terminated Z-0771-2020
The electromagnetic noise exceeded the upper limit of the Electromagnetic Compatibility Standard (EMC: IEC 60601-1-2)
-
- Terminated Z-2711-2016
Software version 1.08 and 1.09 for the Specular Microscope CEM 530 included a change of analysis results feature that was not reviewed and approved by the FDA.
Timeline
- Cleared FDA 510(k) K130565
- Cleared FDA 510(k) K151706
- Recall initiated FDA recalls Z-2711-2016
- Listed FDA GUDID 04987669100530
- Cleared FDA 510(k) K173980
- Recall initiated FDA recalls Z-0771-2020
- Registered EUDAMED 4987669211G5
- Certificate issued EUDAMED 4202074CE01
- Certificate expired EUDAMED 4202074CE01
- Certificate expired EUDAMED 4987669211G5
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Expired
- Not covered
- European Union
- United States
Specification
- Trade name
- Specular Microscope Cem-530 EUDAMEDSpecular Microscope GUDID
- Generic name
- Ophthalmic specular microscope
- Model / reference
- CEM-530, B01E008
- Primary DI / UDI-DI
- 04987669100530
- Basic UDI-DI
- 4987669211G5
- FDA product code
- NQE
- EMDN code
- Z12120116, Z12120199
- GMDN term
- Ophthalmic specular microscope
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 886.1850
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- JP-MF-000040151
- Authorised representative
- NIDEK SA FR-AR-000000341
Similar devices in this category
Other devices filed under PACHYMETERS.