Skip to content

SPETZLER ROUND HANDLE APPLIERS - C-3753

by Nmt Medical, Inc.

510(k) K994191

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK994191 Date8 Feb 2000ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
HCI
Models / Variants
C-3753
Device Class
Class II
Regulation
21 CFR Part 882.4175
Advisory Committee
Neurology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Spetzler Round Handle Appliers are surgical instruments classified as aneurysm clip appliers, designed specifically for use with titanium aneurysm clips during neurosurgical procedures. These devices are engineered to assist neurosurgeons in the precise application of clips to intracranial aneurysms, facilitating secure occlusion while minimising trauma to surrounding tissues.

These appliers are intended for single-use in sterile operating room environments and are regulated under FDA 510(k) clearance (K994191) as Class II devices under regulation 882.4175. Models C-3753, C-3753T, C-3754, and C-3754T are supplied sterile and are compatible with MRI-safe titanium aneurysm clips. Proper storage requires adherence to manufacturer guidelines to maintain sterility and functionality.

Other devices from Nmt Medical, Inc.

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Are these appliers reusable or intended for single-use in the operating room?

    These Spetzler Round Handle Appliers (models C-3753, C-3753T, C-3754, and C-3754T) are explicitly designed for single-use only in sterile operating room environments. The manufacturer emphasizes this to ensure sterility and functionality during neurosurgical procedures, particularly when applying titanium aneurysm clips.

  • What types of aneurysm clips are these appliers compatible with, and do they work with MRI-safe materials?

    The Spetzler Round Handle Appliers are engineered specifically for use with MRI-safe titanium aneurysm clips. This compatibility ensures they can be safely used in MRI environments without interference, which is critical for postoperative imaging of intracranial aneurysms.

  • How should I store these appliers to maintain their sterility and performance?

    To preserve sterility and functionality, these appliers must be stored according to the manufacturer’s guidelines. Since they are supplied sterile and intended for single-use, proper packaging and handling (e.g., avoiding contamination or exposure to moisture) are essential before use in the operating room.

  • What distinguishes the different models (e.g., C-3753 vs. C-3754) of these appliers?

    While the exact differences between the models (C-3753, C-3753T, C-3754, C-3754T) aren’t detailed in the specifications, the ‘T’ suffix (e.g., C-3753T) often denotes a titanium variant or a slight modification in design (e.g., enhanced grip or ergonomics). For precise distinctions, refer to the manufacturer’s documentation or contact Nmt Medical directly, as these variations may affect handling or clip compatibility.

  • What regulatory pathway was followed for FDA clearance of these aneurysm clip appliers?

    These appliers were cleared through the FDA’s 510(k) process (traditional pathway, K994191) under Class II regulation 882.4175, with a substantially equivalent (SESE) determination by the Neurology (NE) Advisory Committee. The clearance confirms they meet FDA standards for aneurysm clip appliers in neurosurgery, though clinical use remains at the surgeon’s discretion.