Skip to content

STA® - System Control N + P 00678

by Diagnostica Stago

Ref 00678

STA - System Control N + P 00678 is a multiple coagulation marker IVD (EU IVDD general IVD; FDA Class II) made by Diagnostica Stago, registered in EUDAMED on 21 Oct 2026 (Basic UDI-DI B-03607450006780), cleared under FDA 510(k) K943518 on 21 Mar 1995 and listed in FDA GUDID since 15 Sep 2016 (UDI-DI 03607450006780), active as of 12 Nov 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE IVDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K943518

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDD EUDAMED NumberB-03607450006780 Basic UDI-DI 03607450006780UDI-DIDate21 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number03607450006780 UDI-DI Date15 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK943518 Date21 Mar 1995DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-03607450006780 registered 21 Oct 2026 Active
  • FDA 510(k) K943518 decided 21 Mar 1995 Active
  • FDA GUDID UDI-DI 03607450006780 listed 15 Sep 2016 Listed

Recalls

2 recalls · FDA

    • Terminated Z-0738-2020 FDA Class II initiated 18 Nov 2019 UDI-DI 03607450006780 listed

    A positive bias was confirmed to exists on the STA - Unicalibrator levels with STA - Deficient IX and STA - Deficient VIII when compared to the International Standard (IS) for factor VIII or IX. This bias is also observed on several External Quality Assessment (EQA) results.

    • Terminated Z-1044-2012 FDA Unclassified (pre-2012) initiated 23 Aug 2011

    Factor VIII quality control results are being recovered below the assigned ranges for STA System Control N+P.

Timeline

5 dated events

  1. Cleared FDA 510(k) K943518
  2. Recall initiated FDA recalls Z-1044-2012
  3. Listed FDA GUDID 03607450006780
  4. Recall initiated FDA recalls Z-0738-2020
  5. Registered EUDAMED B-03607450006780

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
STA® - System Control N+P EUDAMED
STA® - System Control N + P GUDID
Generic name
Multiple coagulation marker IVD, control
Model / reference
00678
Primary DI / UDI-DI
03607450006780
Basic UDI-DI
B-03607450006780
510(k) Number
FDA product code
GGN, GGC
EMDN code
W0103020702 Control plasma for haemostasis
GMDN term
Multiple coagulation marker IVD, control
Device class
Class IVD General EUDAMED
Class II GUDID
Regulation number
864.5425
EU registration type
Legacy device (under a directive)
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IVD General
GUDID
Class II

Device class is stated on each registry's own scale: Class IVD General in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under CONTROL PLASMA FOR HAEMOSTASIS.

Other devices from Diagnostica Stago

See all devices from Diagnostica Stago →

Properties

  • Contains human tissues or cells
  • Contains animal tissues or cells
  • Reagent
  • IVD kit
  • Professional testing
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (15, all answered No)