Steris System 1 Processor and 20 Sterilant
by Steris C/O Medical Device Consultants, Inc.
510(k) K875280
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK875280 | Date13 Sep 1988 | StatusActive |
Recalls
-
- Terminated Z-2462-2008
During ongoing product development testing, it was discovered that, when the two inflow barbs on adapter 201048 # 4 are in a position to face one direction, the top Barblock may interfere with the top surface of bottom barb of the adapter. The interference may cause the plunger on the suction side to lift slightly which may affect flow of sterilant into the suction lumen.
-
- Terminated Z-0765-04
A defective port adapter may affect the sterilization process of the attached endoscope.
-
- Terminated Z-0547-03
The Steris device may not attach properly to retrofitted Olympus bronchoscopes, and become loose during the sterile processing cycle.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- MED
- Device Class
- Class II
- Regulation
- 21 CFR Part 880.6885
- Advisory Committee
- General Hospital
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Steris System 1 Processor and Sterilant is a Liquid Chemical Sterilant Processing System designed for automated chemical sterilization of medical devices. It utilizes S40 Sterilant to achieve high-level disinfection and sterilization, targeting microbial contamination, including bacterial endospores, within device loads. The system is engineered to ensure thorough penetration of sterilant into complex geometries, such as port surfaces and lumens, which may be difficult to reach in other reprocessing methods.
This device is supplied as a reusable processor paired with a liquid chemical sterilant for automated use in healthcare settings. It is intended for general hospital applications and has received FDA 510K clearance under the Traditional pathway, classified as a Class II medical device. The system requires preventive maintenance and is not MRI-safe. No specific sterility or single-use designation is noted in the regulatory data, though the sterilant is applied in a controlled, automated process to ensure efficacy. Authorizations are tied to registration numbers and FEI numbers listed under the 880.6885 regulation.
Questions
AI-generated answers, 1 Oct 2026
What is the Steris System 1 Processor and 20 Sterilant used for?
The Steris System 1 Processor and 20 Sterilant is designed for automated chemical sterilization of medical devices in healthcare settings. It uses S40 Sterilant to achieve high-level disinfection and sterilization, targeting microbial contamination—including bacterial endospores—within device loads. The system is particularly effective for complex geometries like ports and lumens that may be difficult to sterilize using other methods.
How is the Steris System 1 Processor supplied, and is it reusable?
The Steris System 1 Processor is supplied as a reusable automated device paired with a liquid chemical sterilant (S40 Sterilant). The processor itself is not single-use; it is intended for repeated use in healthcare environments, provided it undergoes required preventive maintenance to ensure proper function and sterility of reprocessed devices.
Is the Steris System 1 Processor sterile or single-use?
The Steris System 1 Processor is not designated as sterile or single-use in the regulatory data. Instead, the sterilant (S40) is applied in a controlled, automated process within the system to ensure the efficacy of sterilization for medical devices. The processor itself is reusable, but its performance depends on proper maintenance and adherence to the manufacturer’s guidelines.
What types of medical devices can be sterilized using the Steris System 1 Processor?
The Steris System 1 Processor is intended for general hospital applications, meaning it can be used to sterilize a wide range of medical devices commonly found in healthcare settings. This includes devices with complex geometries, such as those with ports, lumens, or intricate surfaces, where thorough sterilant penetration is critical to ensure microbial elimination.
Does the Steris System 1 Processor require any special storage or maintenance?
Yes, the Steris System 1 Processor requires preventive maintenance to ensure its continued functionality and the sterility of reprocessed devices. While the regulatory data does not specify storage conditions beyond typical healthcare environments, adherence to the manufacturer’s maintenance protocols—such as cleaning, calibration, and part replacement—is essential to maintain performance and compliance with sterilization standards.