Strata II Adjustment Kit 45805
Strata II Adjustment Kit 45805 is a cerebrospinal fluid shunt valve programmer (FDA Class II; FDA product code JXG, Shunt, central nervous system and components) made by Medtronic PS Medical, cleared under FDA 510(k) K060681 on 15 Sep 2006 and listed in FDA GUDID since 1 Dec 2022 (UDI-DI 00763000281274), active as of 23 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00763000281274 | Date1 Dec 2022 | StatusListed |
| United States | FDA 510(k)SESE | NumberK060681 | Date15 Sep 2006 | StatusActive |
Official records
- AccessGUDID record 00763000281274
- FDA 510(k) database K060681
From the FDA record
- Device description
- KIT 45805 FP STRATA 2 ADJUSTMENT
- MRI safety
- MR Unsafe
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K060681 decided 15 Sep 2006 Active
- FDA GUDID UDI-DI 00763000281274 listed 1 Dec 2022 Listed
Recalls
-
- Ongoing Z-1116-2021
Potential for variation in radiopaque marking visibility under radiographic imaging for adjustable and fixed-pressure valves that are used in the management of hydrocephalus
-
- Terminated Z-1121-2017
Medtronic Neurosurgery initiated a recall after receiving five (5) Product Experiences between February 15, 2015 and August 23, 2016 reporting of discrepancies between the pressure/performance level (PL) at which the valve was set and the readings determined via an x-ray image.
Timeline
- Cleared FDA 510(k) K060681
- Recall initiated FDA recalls Z-1121-2017
- Recall initiated FDA recalls Z-1116-2021
- Listed FDA GUDID 00763000281274
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Strata II Adjustment Kit
- Generic name
- Cerebrospinal fluid shunt valve programmer
- Model / reference
- 45805
- Primary DI / UDI-DI
- 00763000281274
- 510(k) Number
- FDA product code
- JXG
- GMDN term
- Cerebrospinal fluid shunt valve programmer
- Device class
- Class II
- Regulation number
- 882.5550
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Similar devices in this category
Other devices filed under Cerebrospinal fluid shunt valve programmer.
- CODMAN CERTAS® 828859 82-8859 by Integra LifeSciences Switzerland Sàrl
- CODMAN® CERTAS™ 828851 82-8851 by Integra LifeSciences Switzerland Sàrl
- CODMAN® CERTAS™ Plus 828852 82-8852 by Integra LifeSciences Production Corporation
- CODMAN® HAKIM® 823190R 82-3190R by Integra LifeSciences Production Corporation
- StrataVarius® 45806 by Medtronic PS Medical