Surfix 286320ND is an orthopaedic bone screw (FDA Class II) made by Newdeal Sas, cleared under FDA 510(k) K093163 on 15 Dec 2009 (4 earlier submissions) and listed in FDA GUDID since 9 Oct 2017 (UDI-DI 10381780049777), active as of 23 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10381780049777 | Date9 Oct 2017 | StatusListed |
| United States | FDA 510(k)SESE | NumberK093163 | Date15 Dec 2009 | StatusActive |
Official records
- AccessGUDID record 10381780049777
- FDA 510(k) database K093163
- FDA 510(k) database K091609
- FDA 510(k) database K070447
- FDA 510(k) database K063820
- FDA 510(k) database K070241
From the FDA record
- Device description
- Stainless steel Newdeal non sterile locking system fixation consists of screws and washers. This system is available in different sizes. The osteosynthesis screws are fixed to the bone through the plate holes, creating a single implant/screw unit. The system is locked by means of washers drilled into the threaded lipped sockets at the top of each hole, thus blocking each screw head.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K093163 decided 15 Dec 2009 Active
- FDA GUDID UDI-DI 10381780049777 listed 9 Oct 2017 Listed
Recalls
-
- Terminated Z-2123-2012
Incorrect technique applied may cause potential rupture of the tibialis anterior tendon during surgery.
-
- Terminated Z-0955-2011
Integra LifeSciences Corporation has decided to initiate a voluntary recall of the Uni-Comp Kits due to inaccurate information relative to the recommended sterilization parameters described in the products Instructions for Use (IFU). The sterilization parameters noted in the Uni-Comp IFU were incorrect. It is noted that the sterilization recommendations in the UNI-Comp IFU in which the Exposure
-
- Terminated Z-0307-2009
Reports of the Uni-CP Compression Forceps breaking during the Compression of the Uni-CP plate
Timeline
- Cleared FDA 510(k) K063820
- Cleared FDA 510(k) K070241
- Cleared FDA 510(k) K070447
- Recall initiated FDA recalls Z-0307-2009
- Cleared FDA 510(k) K091609
- Cleared FDA 510(k) K093163
- Recall initiated FDA recalls Z-0955-2011
- Recall initiated FDA recalls Z-2123-2012
- Listed FDA GUDID 10381780049777
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Surfix
- Generic name
- Orthopaedic bone screw, non-bioabsorbable, non-sterile
- Model / Ref / Catalog
- 286320ND
- Primary DI / UDI-DI
- 10381780049777
- FDA product code
- LXT, HRS
- GMDN term
- Orthopaedic bone screw, non-bioabsorbable, non-sterile
- Device class
- Class II
- Regulation number
- 888.3030
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices in this category
Other devices filed under Orthopaedic bone screw, non-bioabsorbable, non-sterile.
- Cannulated Screw 110007575 by Biomet Orthopedics, Inc.
- IO FiX 118-40038 by Extremity Medical, LLC
- ACUMED 30-0269 by ACUMED LLC
- MULTIDIRECTIONAL SCREW 8163-35-028 816335028 by Biomet Orthopedics, Inc.
- Omni Stable AF 144-35058 by Extremity Medical, LLC
- FITBONE TAA SYSTEM 1 60000998 by ORTHOFIX SRL
- FITBONE TAA SYSTEM 1 60001001 by ORTHOFIX SRL
- TraumaOne SYSTEM 45-2114 by BIOMET MICROFIXATION, INC
- TraumaOne SYSTEM 45-2108 by BIOMET MICROFIXATION, INC
- ACUMED CO-3250 by ACUMED LLC