Surgical Claw straight 07711
by Med-El Elektromedizinische Geräte Gesellschaft m.b.H.
Surgical Claw straight 07711 is a cochlear electrode array introducer (FDA Class III; FDA product code MCM, Implant, Cochlear) made by Med-El Elektromedizinische Geräte Gesellschaft m.b.H., approved under FDA PMA P000025 on 20 Aug 2001 and listed in FDA GUDID since 23 Sep 2014 (UDI-DI 09008737077112), active as of 23 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number09008737077112 | Date23 Sep 2014 | StatusListed |
| United States | FDA PMAAPPR | NumberP000025 | Date20 Aug 2001 | StatusActive |
Official records
- AccessGUDID record 09008737077112
- FDA PMA database P000025
From the FDA record
- Device description
- Reusable Surgical Tool
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA PMA P000025 decided 20 Aug 2001 Active
- FDA GUDID UDI-DI 09008737077112 listed 23 Sep 2014 Listed
Recalls
-
- Ongoing Z-2356-2024
A small number of devices may have a higher probability of a crack within the internal electronics substrate which could result in a non-functional device.
-
- Terminated Z-2136-2019
- Terminated Z-2137-2019
- Terminated Z-2138-2019
Devices were distributed despite the Helium-fine leak test results not being within the cochlear implant standards specification.
Timeline
- Approved FDA PMA P000025
- Listed FDA GUDID 09008737077112
- Recall initiated FDA recalls Z-2136-2019
- Recall initiated FDA recalls Z-2137-2019
- Recall initiated FDA recalls Z-2138-2019
- Recall initiated FDA recalls Z-2356-2024
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Trade name
- Surgical Claw straight
- Generic name
- Cochlear electrode array introducer, reusable
- Model / reference
- 07711
- Primary DI / UDI-DI
- 09008737077112
- PMA number
- FDA product code
- MCM
- GMDN term
- Cochlear electrode array introducer, reusable
- Device class
- Class III
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices
Other devices filed under FDA product code MCM (Implant, Cochlear).
- Cochlear™ Battery Cover Z491367 by Cochlear
- Nucleus Z327113 by Cochlear
- Neuro Cochlear Implant System by Oticon Medical
- Sky CI™ M90 CI-5295 by Advanced Bionics
- Nucleus 24 Cochlear Implant System by Cochlear Americas
- Nucleus 22 Channel Cochlear Implant for Children by Cochlear Americas
- Combi 40+ Cochlear Implant System by Med-El Corp.
- HiResolution Bionic Ear System by Advanced Bionics
Other devices from Med-El Elektromedizinische Geräte Gesellschaft m.b.H.
See all devices from Med-El Elektromedizinische Geräte Gesellschaft m.b.H. →