Symbia_Intevo_2 10764802
by Siemens Medical Solutions USA, Inc.
Part of a family of 12 devices: see the family page
Ref 10764802Model SPECT-CT_10_IIb_HES
Symbia_Intevo_2 10764802 is a SPECT/CT system (EU MDR Class IIb; FDA Class II; FDA product code KPS, System, tomography, computed, emission) made by Siemens Medical Solutions USA, Inc., registered in EUDAMED on 19 Jun 2026 (Basic UDI-DI 0405686900135UT) and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 04056869001227), active as of 24 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingDocuments
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0405686900135UT 04056869001227 | Date19 Jun 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04056869001227 | Date24 Sep 2016 | StatusListed |
Official records
- EUDAMED public site 0405686900135UT
- AccessGUDID record 04056869001227
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0405686900135UT registered 19 Jun 2026 Active
- FDA GUDID UDI-DI 04056869001227 listed 24 Sep 2016 Listed
Recalls
-
- Terminated Z-2437-2015
Fuses with the improper amperage rating were installed in the Symbia S, Symbia T Series and Symbia lntevo systems. These fuses, in conjunction with a specific failure mode of the Power Controller assembly, could lead to the overheating of the assembly.
Timeline
- Recall initiated FDA recalls Z-2437-2015
- Listed FDA GUDID 04056869001227
- Registered EUDAMED 0405686900135UT
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Symbia_Intevo_2
- Generic name
- SPECT/CT system
- Device name
- SPECT-CT_10_IIb_HES
- Model / reference
- 10764802, SPECT-CT_10_IIb_HES
- Primary DI / UDI-DI
- 04056869001227
- Basic UDI-DI
- 0405686900135UT
- FDA product code
- KPS
- EMDN code
- Z11020201 CT/gamma camera systems
- GMDN term
- SPECT/CT system
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.1200
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under CT/GAMMA CAMERA SYSTEMS.
- NM/CT 870 DR by GE Medical Systems Israel, Functional Imaging
- NMCT 860 by GE Medical Systems Israel, Functional Imaging
- Campo 100110315001 by Liaoning Campo Imaging Medical Co., Ltd.
- Campo 100120315001 by Liaoning Campo Imaging Medical Co., Ltd.
- VERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464) by Spectrum Dynamics Medical ltd