Skip to content

Synchron Systems C-Reactive Protein (C-RP) Reagent; Synchron Systems CX C-RP Calibrator

by Beckman Coulter, Inc.

510(k) K021572

Active European Union and United States

CE IVDD 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE 510(k) Substantially Equivalent · Traditional NumberK021572 Date19 Jul 2002ClearedStatusActive
European UnionCE/IVDD EUDAMED Number— Date—StatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k)

510(k) Number
FDA Product Code
DCN
Device Class
Class II
Regulation
21 CFR Part 866.5270
Advisory Committee
Immunology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Synchron Systems C-Reactive Protein (C-RP) Reagent and Synchron Systems CX C-RP Calibrator are in vitro diagnostic devices designed for the quantitative measurement of C-reactive protein in human serum or plasma. C-reactive protein is a biomarker used to detect inflammation, infection, or tissue injury, and these reagents enable precise clinical assessment in laboratory settings.

These devices are intended for use with the Synchron Systems chemistry analyzer, supplied as sterile, single-use reagents and calibrators. The reagents and calibrator are classified as Class II devices under FDA regulations (510(k) clearance) and comply with the In Vitro Diagnostic Device Directive (IVDD). Storage and handling follow manufacturer guidelines to maintain accuracy and reliability, ensuring proper diagnostic performance in clinical immunology applications.

Other devices from Beckman Coulter, Inc.

See all devices from Beckman Coulter, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical applications does the Synchron Systems C-Reactive Protein (C-RP) Reagent support in a lab setting?

    The Synchron Systems C-Reactive Protein (C-RP) Reagent is designed for the quantitative measurement of C-reactive protein in human serum or plasma. Clinically, this biomarker helps detect inflammation, infection, or tissue injury, enabling precise diagnostic assessments in laboratory settings. It is specifically intended for use with the Synchron Systems chemistry analyzer to support clinical immunology applications.

  • Are the Synchron Systems C-RP Reagent and CX C-RP Calibrator single-use or reusable, and how should they be stored?

    Both the Synchron Systems C-Reactive Protein (C-RP) Reagent and the Synchron Systems CX C-RP Calibrator are supplied as sterile, single-use items. To maintain accuracy and reliability, they must be stored and handled according to the manufacturer’s guidelines, which ensure proper diagnostic performance.

  • What analyzer is required to use the Synchron Systems C-Reactive Protein (C-RP) Reagent, and is it compatible with other systems?

    The Synchron Systems C-Reactive Protein (C-RP) Reagent is explicitly designed for use with the Synchron Systems chemistry analyzer. It is not intended for use with other systems, as compatibility and performance are validated only for this specific analyzer.

  • What regulatory pathways have the Synchron Systems C-Reactive Protein (C-RP) Reagent and CX C-RP Calibrator undergone?

    The device has received FDA 510(k) clearance and complies with the In Vitro Diagnostic Device Directive (IVDD). It is classified as a Class II device under FDA regulations, with a substantially equivalent determination by the Immunology (IM) Advisory Committee. The product was filed under the DCN product code and reviewed by the same committee.