Skip to content

SYNCT™ Software CN-SW47

by Luminex Corporation

SYNCT Software CN-SW47 is a medical device (FDA Class II; FDA product code OOI, real time Nucleic acid amplification system) made by Luminex Corporation, cleared under FDA 510(k) K160517 on 12 Apr 2016 (1 earlier submission) and listed in FDA GUDID since 9 Sep 2016 (UDI-DI 00840487100448), active as of 23 Oct 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00840487100448 UDI-DI Date9 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK160517 Date12 Apr 2016DecidedStatusActive

Official records

From the FDA record

Device description
The SYNCT Software is a desktop application that can be utilized by an end-user on a standalone computer, providing users the ability to operate general functions such as Order Management, with or without a Laboratory Information System (LIS), viewing test results, reviewing and preparing test reports, performing software administrative functions, and providing security control for permitted functions.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K160517 decided 12 Apr 2016 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00840487100448 listed 9 Sep 2016 Listed

Recalls

4 recalls · 2 ongoing · FDA

    • Ongoing Z-0042-2025 FDA Class II initiated 5 Sep 2024 on shared 510(k) K152386

    Respiratory pathogen panel may report an elevated rate (7.6% predicted probability of occurrence) of non-specific hMPV target (human Metapneumovirus) results, risk identified predominantly in clinical samples that present positivity for another target, leading to an erroneous co-infection result, can potentially result in hMPV false positives.

    • Ongoing Z-2288-2019 FDA Class II initiated 20 Feb 2019

    Through internal investigation, it was discovered that a portion of side cassette assemblies (SCAs) back side seal (BSS) did not meet design specification, resulting in partially sealed SCAs. The impact of a partial seal of the BSS could result in potential decrease of volume for each solution in the SCAs and decreased sensitivity or stability of the assay.

    • Terminated Z-2292-2019 FDA Class II initiated 29 Jun 2018

    An incorrect control board and firmware installed in some of the Hand Held Barcode Scanners could result in sample/patient mismatch or duplicate results (from other patients specimens) for a patient order.

    • Terminated Z-2094-2017 FDA Class II initiated 19 Apr 2017

    The hand-held barcode scanner that is used as an accessory to enter ARIES cassette and specimen identifications on the ARIES Systems populates patient sample IDs with a previously scanned sample ID when entering orders into an ARIES instrument.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

7 dated events

  1. Cleared FDA 510(k) K152386
  2. Cleared FDA 510(k) K160517
  3. Listed FDA GUDID 00840487100448
  4. Recall initiated FDA recalls Z-2094-2017
  5. Recall initiated FDA recalls Z-2292-2019
  6. Recall initiated FDA recalls Z-2288-2019
  7. Recall initiated FDA recalls Z-0042-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
SYNCT™ Software
Generic name
Laboratory instrument/analyser application software IVD
Model / reference
CN-SW47
Primary DI / UDI-DI
00840487100448
510(k) Number
FDA product code
OOI
GMDN term
Laboratory instrument/analyser application software IVD
Device class
Class II
Regulation number
862.2570
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Laboratory instrument/analyser application software IVD.

Other devices from Luminex Corporation

See all devices from Luminex Corporation →

Properties

  • Prescription use
  • Lot / batch number
Other properties (13, all answered No)