Skip to content

SyncVision Medical Image Processing System 400-0100.10

by Volcano Corporation

Ref 400-0100.10

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, FDA 510(k), GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00845225012434 Basic UDI-DI 00845225012434UDI-DIDate24 Mar 2026RegisteredStatusActive
United StatesFDA 510(k) 510(k) NumberK190626 Date12 Apr 2019IssuedStatusActive
United StatesGUDID listing GUDID Number00845225012434 UDI-DI Date12 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK132558 Date12 Dec 2013DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00845225012434 registered 24 Mar 2026 Active
  • FDA 510(k) K190626 decided 12 Apr 2019 Active· +4 more in the status table
  • FDA GUDID UDI-DI 00845225012434 listed 12 Sep 2016 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-0885-2022 FDA Class II initiated 19 Jan 2022

    If FFR measurement(s) are made prior to an iFR/FFR co-registration/pullback in the same procedural session, this could result in incorrect iFR/FFR Co-Registration results to be displayed, that may cause users to mistakenly use incorrect measurements, leading to inappropriate patient treatment. Image acquisition and processing system operators manual to be updated to include workflow alternatives.

Timeline

8 dated events

  1. Cleared FDA 510(k) K132558
  2. Cleared FDA 510(k) K151904
  3. Cleared FDA 510(k) K161756
  4. Listed FDA GUDID 00845225012434
  5. Cleared FDA 510(k) K172574
  6. Cleared FDA 510(k) K190626
  7. Recall initiated FDA recalls Z-0885-2022
  8. Registered EUDAMED B-00845225012434

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • United States FDA 510(k) Active
  • European Union CE/MDD Active

Specification

EUDAMED · 510(k) · GUDID

Full name
SyncVision Medical Image Processing System
Trade name
SyncVision Medical Image Processing System EUDAMED
SyncVision System GUDID
Generic name
Cardiovascular ultrasound imaging system
Model / Ref / Catalog
400-0100.10
Primary DI / UDI-DI
00845225012434
Basic UDI-DI
B-00845225012434
510(k) Number
FDA product code
OWB
EMDN code
C010499 Angiography and hemodynamics devices - other
GMDN term
Cardiovascular ultrasound imaging system
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1650
System or procedure pack
System which is a device in itself
EU registration type
Legacy device (under a directive)
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000020094
Authorised representative
Volcano Europe BE-AR-000000929

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The SyncVision Medical Image Processing System is a Class IIa medical imaging device (Nomenclature Code: C010499) designed for processing fluoroscopic images. It provides quantitative analysis of arterial dimensions and enhances visualization of stent deployment regions during interventional cardiology procedures.

This system is used in catheterization labs for real-time in-procedure imaging and offline post-procedural analysis. It is non-sterile, non-reusable, and non-implantable, with no latex components. The device carries FDA 510(k) and MDD authorizations, and its UDI is B-00845225012434. It operates as an active medical device with measuring functionality.

Similar devices in this category

Other devices filed under ANGIOGRAPHY AND HEMODYNAMICS DEVICES - OTHER.

Other devices from Volcano Corporation

See all devices from Volcano Corporation →

Properties

  • Measuring function
  • Prescription use
  • Lot / batch number
  • Serial number
  • Manufacturing date
Other properties (18, all answered No)