Synelisa TGAB

by Elias U.S.A., Inc.

510(k) K915134

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK915134 Date8 Apr 1992ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
JZO
Device Class
Class II
Regulation
21 CFR Part 866.5870
Advisory Committee
Immunology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Synelisa TGAB is a Thyroid Autoantibody Test System, designed for the qualitative detection of thyroid peroxidase (TPO) antibodies in serum or plasma. This immunology device aids in the diagnosis of autoimmune thyroid diseases, such as Hashimoto’s thyroiditis and Graves’ disease, by identifying circulating autoantibodies linked to thyroid dysfunction.

This system is intended for use in clinical laboratory settings and is supplied as a single-use diagnostic kit. It requires no special storage conditions beyond refrigeration and is classified under FDA product code JZO as a Class II device. The device was cleared via a Traditional 510(k) pathway (K915134) and is regulated under 21 CFR 866.5870 for immunology testing. No MRI safety or reusable components are specified.

Other devices from Elias U.S.A., Inc.

See all devices from Elias U.S.A., Inc. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical conditions can the Synelisa TGAB help diagnose, and how does it work?

    The Synelisa TGAB is designed to detect thyroid peroxidase (TPO) antibodies in serum or plasma, which are linked to autoimmune thyroid diseases. By identifying these circulating autoantibodies, it aids in diagnosing conditions like Hashimoto’s thyroiditis and Graves’ disease, helping clinicians assess thyroid dysfunction. The test functions as a qualitative immunology assay, providing a yes/no result for antibody presence.

  • Is the Synelisa TGAB intended for use outside of clinical laboratories, or is it strictly laboratory-based?

    The Synelisa TGAB is explicitly intended for use *only* in clinical laboratory settings. It is supplied as a single-use diagnostic kit, meaning it requires professional handling and interpretation by trained personnel in a controlled lab environment.

  • How should the Synelisa TGAB be stored, and does it require any special handling?

    The Synelisa TGAB does not require special storage conditions beyond standard refrigeration. This makes it convenient for laboratories to maintain without additional infrastructure, though it should be kept in its original packaging until use.

  • Is the Synelisa TGAB a reusable device, or is it designed for single-use only?

    The Synelisa TGAB is explicitly described as a single-use diagnostic kit. This design ensures patient safety and consistency, as each test is intended for one use only and cannot be reused or reprocessed.

  • What regulatory pathway was followed for the Synelisa TGAB’s clearance, and what does that mean for its use?

    The Synelisa TGAB was cleared via the FDA’s Traditional 510(k) pathway (K915134) and is classified as a Class II device under product code JZO. This means it was determined to be substantially equivalent to a legally marketed device and is regulated under 21 CFR 866.5870 for immunology testing, ensuring it meets FDA safety and performance standards for clinical use.