Synthes Lcp Proximal Tibia Plates Line Extension
510(k) K052390
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK052390 | Date7 Oct 2005 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- HRS
- Device Class
- Class II
- Regulation
- 21 CFR Part 888.3030
- Advisory Committee
- Orthopedic
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 6 Oct 2026
The Synthes Lcp Proximal Tibia Plates Line Extension is a metallic bone fixation implant designed for the surgical treatment of proximal tibia fractures and related conditions. It features a limited-contact, low-profile design contoured to match proximal tibia anatomy. The device merges conventional plating techniques with locking screw technology, enabling surgeons to create a fixed-angle construct while using familiar plating techniques.
The Synthes Lcp Proximal Tibia Plates Line Extension is available in left and right configurations with shaft lengths from 298 mm to 370 mm and 16 to 20 shaft holes, and in 3.5- and 4.5-mm sizes. It is supplied for use in orthopedic procedures and has received FDA 510K authorization. The device is intended for use in the treatment of fractures of the proximal tibia in adults and adolescents in which the growth plates have fused.
Other devices from Synthes (Usa)
Questions
AI-generated answers, 6 Oct 2026
What is the Synthes LCP Proximal Tibia Plates Line Extension used for?
The Synthes LCP Proximal Tibia Plates Line Extension is used for the surgical treatment of proximal tibia fractures and related conditions in adults and adolescents with fused growth plates.
What sizes and configurations are available?
The device is available in left and right configurations, with shaft lengths from 298 mm to 370 mm, 16 to 20 shaft holes, and in 3.5- and 4.5-mm sizes.
Is the Synthes LCP Proximal Tibia Plates Line Extension supplied sterile?
The description does not explicitly state that the device is supplied sterile, but it is intended for use in orthopedic procedures.
What is the regulatory status of the Synthes LCP Proximal Tibia Plates Line Extension?
The device has received FDA 510K authorization, indicating that it is substantially equivalent to a predicate device.