# Sys\*stim 220

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/sys-stim-220-lih>
- Manufacturer: [Mettler Electronics Corp.](https://devicerts.com/manufacturers/fda-fei-2013558) (FDA registration: United States)
- Name in the registry: SYS\*STIM 220
- Device class: Class II (US FDA)
- FDA product code: LIH

## Overview

*AI-generated summary, 2026-10-01. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The SysStim 220 is an interferential current therapy device, classified as a Class II medical electrical device. It delivers interferential current stimulation to promote neuromuscular function, pain relief, and tissue healing through the application of alternating electrical currents that interfere constructively at the target site.

This device is intended for use in clinical and home settings by trained professionals or under medical supervision. Supplied as a reusable medical electrical device, it requires proper maintenance and servicing as outlined in its operational manual. The SysStim 220 holds an FDA 510(k) clearance under the traditional pathway, with a decision date of April 27, 1989, and is regulated under the regulation number 882.5890. No third-party review or sterility requirements are specified.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K883080 · decision 1989-04-27 · decision SESE · status: Active

## Recalls

No recall on record.

## Identifiers

- 510(k) Number: K883080 [FDA 510(k)]
- FDA product code: LIH [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 882.5890 [FDA 510(k)]
- Advisory committee: Neurology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Sys\*stim 220, Mettler Electronics Corp. deviCERTS medical device catalogue. https://devicerts.com/devices/sys-stim-220-lih (data as of 2026-11-16).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-16
- JSON: <https://devicerts.com/devices/sys-stim-220-lih.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/sys-stim-220-lih
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.