Skip to content

Tacker OMS-TTSD

by Covidien LP

Tacker OMS-TTSD is a soft-tissue/mesh anchor (FDA Class II) made by Covidien LP, cleared under FDA 510(k) K090470 on 14 May 2009 and listed in FDA GUDID since 2 Sep 2015 (UDI-DI 10884521070486), active as of 23 Oct 2026. 2 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

510(k) K090470

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10884521070486 UDI-DI Date2 Sep 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK090470 Date14 May 2009DecidedStatusActive

Official records

From the FDA record

Device description
Fixation Device
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K090470 decided 14 May 2009 Active
  • FDA GUDID UDI-DI 10884521070486 listed 2 Sep 2015 Listed

Recalls

2 recalls · 1 ongoing · FDA

    • Ongoing Z-0986-2024 FDA Class II initiated 16 Nov 2023

    Packaging of the device may cause a low seal strength in the side seal of the foil pouch potentially resulting in a sterile/moisture barrier breach, compromising the product sterility

    • Terminated Z-1157-2010 FDA Unclassified (pre-2012) initiated 8 Feb 2010

    Fixation device may fail to fire and staple.

Timeline

4 dated events

  1. Cleared FDA 510(k) K090470
  2. Recall initiated FDA recalls Z-1157-2010
  3. Listed FDA GUDID 10884521070486
  4. Recall initiated FDA recalls Z-0986-2024

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Tacker
Generic name
Soft-tissue/mesh anchor, non-bioabsorbable
Model / reference
OMS-TTSD
Primary DI / UDI-DI
10884521070486
510(k) Number
FDA product code
GDW, OCW
GMDN term
Soft-tissue/mesh anchor, non-bioabsorbable
Device class
Class II
Regulation number
878.4750, 876.1500
GUDID distribution status
In Commercial Distribution
Size
Outer Diameter — 5 Millimeter

Other devices from Covidien LP

  • Invos PM7100

    Class II
  • Invos PMAC71DOC Open recall

    Class II
  • LigaSure MRASILF19

    Class II
  • Shiley 110860

    Class II

See all devices from Covidien LP →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)