# Talon 00711175

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/talon-00711175-07ef88ce>
- Manufacturer: [US Endoscopy](https://devicerts.com/manufacturers/us-endoscopy) (FDA registration: United States)
- Device class: Class I (EU MDR); Class II (US FDA)
- FDA product code: FGO
- EMDN: G03050199 DIGESTIVE ENDOSCOPY, RETRIEVAL DEVICES - OTHER
- GMDN: Flexible endoscopic tissue manipulation forceps, single-use (33199)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 0724995ENTALONGRSPDEVH5 · UDI-DI 00724995182786 · registered 2026-11-02 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 00724995182786 · listed 2020-03-19 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K962676 · decision 1996-10-04 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1453-2015 · Class II · terminated · initiated 2015-03-10 · the recall lists this device's catalog number (version and lot not checked): A wire component on the distal grasping assembly of the device became detached..
- Z-0006-2013 · Class II · terminated · initiated 2011-11-14: When the outer catheter is either coiled or in a contorted configuration outside of the endoscope and the patient, and excessive force is applied to the handle, the jaws may become inoperable and may become stuck in the open condition.

## Identity

- Trade name: Talon [EUDAMED, FDA GUDID (AccessGUDID)]
- Generic name: Flexible endoscopic tissue manipulation forceps, single-use [FDA GUDID (AccessGUDID)]
- Device name: Grasping Device Talon - Sterile [EUDAMED]
- Model / Ref / Catalog: 00711175 [EUDAMED, FDA GUDID (AccessGUDID)]; Grasping Device Talon - Sterile [EUDAMED]

## Identifiers

- Primary DI / UDI-DI: 00724995182786 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 0724995ENTALONGRSPDEVH5 [EUDAMED]
- 510(k) Number: K962676 [FDA GUDID (AccessGUDID)]
- FDA product code: FGO [FDA GUDID (AccessGUDID)]
- EMDN code: G03050199 [EUDAMED]
- GMDN term: Flexible endoscopic tissue manipulation forceps, single-use (33199) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class I [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 876.4680 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Ireland [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Dimensions & Sizes

- Size: Outer Diameter — 2.5 Millimeter [FDA GUDID (AccessGUDID)]; Length — 160 Centimeter [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): Yes [EUDAMED]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Talon 00711175, US Endoscopy. deviCERTS medical device catalogue. https://devicerts.com/devices/talon-00711175-07ef88ce (data as of 2026-11-29).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-11-07
- Statuses computed as of: 2026-11-29
- JSON: <https://devicerts.com/devices/talon-00711175-07ef88ce.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/talon-00711175-07ef88ce
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
