TDX Cyclosporine and Metabolites Serum Assay
PMA P890025
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA PMAAPRL | NumberP890025 | Date14 Dec 1989 | StatusActive |
Recalls
-
- Terminated Z-0624-06
Patient results reported using calibrators made from new primary material may be falsely decreased by 5-8% compared to results using calibrators made from the previous primary material. An Important Product Information Letter with technical information regarding the Whole Blood Calibrators and Controls, implementing new internal reference standards was issued.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Full name
- Tdx Cyclosporine and Metabolites Serume Assay
- Trade Name
- Td Cyclosporine and Metabolites Serum Assay
- Generic Name
- Fluorescence polarization immunoassay for cyclosporine
- PMA Number
- FDA Product Code
- MGU
- Device Class
- Class II
- Regulation
- 21 CFR Part 862.1235
- Advisory Committee
- Clinical Toxicology
- FDA Decision
- APRL
Overview
AI-generated summary, 18 Sep 2026
The TDX Cyclosporine and Metabolites Serum Assay is a Fluorescence Polarization Immunoassay for quantifying cyclosporine and its metabolites in serum. Classified under Clinical Chemistry, it is designed to measure drug concentrations critical for managing immunosuppression therapy, particularly in organ transplant patients.
This assay is supplied as a reagent kit for use in clinical laboratories equipped with the TDX analyzer system. It is intended for single-use and requires proper storage at controlled temperatures to maintain stability. The device holds FDA PMA approval under PMA number P890025, adhering to regulatory standards for in vitro diagnostic use in the United States.
Other devices from Abbott Laboratories
Questions
AI-generated answers, 18 Sep 2026
What clinical specialty does this assay support, and why is it important for that field?
This assay supports Clinical Chemistry, specifically for managing immunosuppression therapy in organ transplant patients. It quantifies cyclosporine and its metabolites in serum, which is critical for ensuring proper drug dosing to prevent organ rejection while minimizing toxicity. Accurate measurement helps clinicians adjust treatment plans based on real-time patient data.
How is the TDX Cyclosporine and Metabolites Serum Assay supplied, and what does that mean for its use in a lab?
The assay is supplied as a reagent kit designed exclusively for use with the TDX analyzer system in clinical laboratories. This means it cannot be used independently—it requires the analyzer’s infrastructure, calibration, and maintenance protocols. The single-use nature of the kit also implies each test must be prepared fresh, reducing carryover risks but requiring careful inventory management.
Is this device intended for reuse, and if not, what does that imply for cost and workflow?
No, the device is intended for single-use only, as indicated by its classification as a reagent kit. This design eliminates cross-contamination risks but necessitates purchasing multiple kits for routine testing, which may impact budgeting and workflow efficiency. Labs must account for disposal costs and ensure timely reordering to avoid interruptions in immunosuppression monitoring.
What storage conditions are required to maintain the assay’s stability, and why are these important?
The assay requires controlled temperature storage to preserve stability, though exact conditions aren’t specified beyond this general requirement. Proper storage is critical because cyclosporine metabolites can degrade over time if exposed to improper temperatures, leading to inaccurate test results. Clinicians rely on these measurements to fine-tune patient therapy, so stability ensures consistent, reliable data for clinical decision-making.
What does the FDA PMA approval (P890025) mean for healthcare providers using this assay?
The FDA PMA approval (P890025) confirms that the assay meets stringent regulatory standards for in vitro diagnostic use in the United States, ensuring its safety, performance, and clinical validity. For healthcare providers, this approval signals that the assay has undergone rigorous validation for quantifying cyclosporine and its metabolites in serum, supporting evidence-based immunosuppression management in organ transplant patients. It also implies compliance with U.S. regulatory requirements for accuracy and reproducibility.