Techmedica Mueller Type Polyethylene Acetabular Cup
510(k) K925181
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK925181 | Date5 Feb 1993 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Techmedica Mueller Type Polyethylene Acetbul Cup
- 510(k) Number
- FDA Product Code
- JDL
- Device Class
- Class III
- Regulation
- 21 CFR Part 888.3320
- Advisory Committee
- Orthopedic
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
This device is a Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component) as classified by the FDA. It is a cemented acetabular cup constructed from polyethylene, designed to articulate with femoral components in total hip arthroplasty. The device is intended for use in orthopedic surgical procedures to replace the natural hip joint, providing stability and mobility for patients with degenerative joint disease or trauma.
The Mueller Type Polyethylene Acetabular Cup is supplied as a reusable surgical implant, intended for use in sterile operating environments. It is regulated under FDA 510(k) clearance (K925181) and falls under product code JDL, with a classification of Class III. The device is manufactured by Techmedica, Inc., and its design is substantiated as substantially equivalent to predicate devices. No specific MRI safety or single-use designation is noted in the regulatory data.
Other devices from Techmedica, Inc.
Questions
AI-generated answers, 18 Sep 2026
What types of surgical procedures is the Mueller Type Polyethylene Acetabular Cup designed for?
The Mueller Type Polyethylene Acetabular Cup is specifically designed for use in total hip arthroplasty procedures. It is intended to replace the natural hip joint in patients suffering from degenerative joint disease or trauma, providing stability and mobility through articulation with femoral components. It is a semi-constrained, metal-cemented acetabular component.
Is the Mueller Type Polyethylene Acetabular Cup intended for single-use or can it be reused?
The Mueller Type Polyethylene Acetabular Cup is explicitly described as a reusable surgical implant. It is intended for use in sterile operating environments, meaning it can be sterilized and reused for multiple procedures, provided proper sterilization protocols are followed.
What regulatory pathway was followed for FDA clearance of this device, and what does that mean for its safety and equivalence?
The Mueller Type Polyethylene Acetabular Cup received FDA clearance through a 510(k) Traditional Review process, classified under product code JDL as a Class III device. The clearance was granted as substantially equivalent (SESE) to predicate devices, meaning the FDA determined that it has the same intended use and technological characteristics as legally marketed devices. This pathway ensures that the device meets safety and effectiveness standards comparable to existing, cleared alternatives.
Are there any specific sizes or models available for this acetabular cup, and how would I identify them?
The provided data lists multiple FEI numbers (e.g., 3020282716, 1000577893, etc.) associated with this device, which likely correspond to different sizes or variants of the Mueller Type Polyethylene Acetabular Cup. These identifiers are used in regulatory filings and may help distinguish specific models or configurations. For precise sizing details, you would need to consult the manufacturer’s catalog or technical documentation, as the data does not specify exact dimensions or model names.
Does this device have any special considerations regarding MRI safety or compatibility?
The regulatory data for the Mueller Type Polyethylene Acetabular Cup does not explicitly mention MRI safety or compatibility. If MRI imaging is required for patients with this implant, you would need to verify with the manufacturer or consult clinical guidelines, as metal components in hip prostheses can pose risks in magnetic fields. Always confirm compatibility before scheduling MRI procedures.