Skip to content

TEE022

by Esaote S.p.A.

Ref 9600170000

TEE022 (9600170000) is an oesophageal ultrasound imaging transducer (EU MDD Class IIa; FDA Class II; FDA product code ITX, Transducer, Ultrasonic, Diagnostic) made by Esaote S.p.A., registered in EUDAMED on 7 Mar 2022 (Basic UDI-DI B-08056304452047) and listed in FDA GUDID since 27 Sep 2016 (UDI-DI 08056304452047), active as of 22 Oct 2026.

Active European Union. Also listed in GUDID (US).

CE MDD

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

Not checked

No FDA submission to match recalls against

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-08056304452047 Basic UDI-DI 08056304452047UDI-DIDate7 Mar 2022RegisteredStatusActive
United StatesGUDID listing GUDID Number08056304452047 UDI-DI Date27 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Probe TEE022 complete name
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as containing natural rubber latex
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 25 May 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI B-08056304452047 registered 7 Mar 2022 Active
  • FDA GUDID UDI-DI 08056304452047 listed 27 Sep 2016 Listed

Timeline

2 dated events

  1. Listed FDA GUDID 08056304452047
  2. Registered EUDAMED B-08056304452047

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
TEE022 EUDAMED
Tee GUDID
Generic name
Oesophageal ultrasound imaging transducer, reusable
Model / reference
9600170000
Primary DI / UDI-DI
08056304452047
Basic UDI-DI
B-08056304452047
FDA product code
ITX
EMDN code
Z1104020301 Transesophageal ultrasound probes, two–dimensional
GMDN term
Oesophageal ultrasound imaging transducer, reusable
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1570
EU registration type
Legacy device (under a directive)
EU market of registration
Italy
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II
Contains latexEUDAMED
No
GUDID
Yes

Registry differences

EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:

  • Contains latex UDI-DI 08056304452047: EUDAMED states No, FDA GUDID states Yes.

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
IT-MF-000019024

Similar devices in this category

Other devices filed under TRANSESOPHAGEAL ULTRASOUND PROBES, TWO–DIMENSIONAL.

Other devices from Esaote S.p.A.

See all devices from Esaote S.p.A. →

Properties

  • Contains latex NoEUDAMEDYesGUDID
  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (19, all answered No)