Telectronics #030-253 Bifurcated
510(k) K831303
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK831303 | Date25 May 1983 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DTB
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3680
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
This device is a Permanent Pacemaker Electrode, classified as a Class III medical device under FDA regulations. It is designed for implantation within the cardiovascular system to provide electrical stimulation for pacing purposes, ensuring proper heart rhythm in patients with bradycardia or other conduction disorders. The bifurcated design allows for dual lead attachment, facilitating precise electrode positioning within the heart chambers.
The Teletronics #030-253 is supplied sterile and intended for single-use implantation by qualified healthcare professionals in a controlled clinical setting. It is regulated under FDA 510(k) clearance (K831303) and adheres to the regulatory requirements outlined in 21 CFR 870.3680. Storage and handling must comply with sterile medical device protocols to maintain integrity prior to use.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the Teletronics #030-253 Bifurcated device, and how does its design benefit patients?
The Teletronics #030-253 is a permanent pacemaker electrode designed to maintain proper heart rhythm in patients with bradycardia or conduction disorders by delivering electrical stimulation. Its bifurcated design allows for dual lead attachment, enabling precise electrode positioning within the heart chambers, which enhances pacing accuracy and stability for patients requiring synchronized stimulation.
Is this device intended for reuse, or is it meant to be implanted once and discarded?
The Teletronics #030-253 is sterile and intended for single-use only. It must be implanted by qualified healthcare professionals in a controlled clinical setting, and proper sterile handling protocols must be followed to ensure device integrity before use. Reuse is not recommended or supported by the manufacturer.
How should this device be stored to maintain its sterility and functionality before implantation?
Since the Teletronics #030-253 is supplied sterile, it must be stored according to standard sterile medical device protocols. This includes keeping it in its original packaging, in a clean, dry environment, and away from direct sunlight or extreme temperatures. Always verify the sterility indicators before use to ensure the device remains uncontaminated.
What regulatory pathway does this device follow, and which FDA requirements does it comply with?
The Teletronics #030-253 is classified as a Class III medical device under FDA regulations and has received 510(k) clearance (K831303). It adheres to the requirements outlined in 21 CFR 870.3680, ensuring compliance with FDA standards for permanent pacemaker electrodes. The device was reviewed by the Cardiovascular (CV) Advisory Committee and determined to be substantially equivalent to a predicate device.