The Imed Orion Infusion Pump and Administration Sets

by Imed Corp.

510(k) K950419

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK950419 Date21 Jun 1995ClearedStatusActive

Recalls

12 recalls · 1 ongoing · FDA

    • Ongoing Z-0026-2018 FDA Class II initiated 9 Aug 2017

    The recalling firm has received reports of increased or decreased flows that have occurred in certain pumps.

    • Terminated Z-2700-2017 FDA Class II initiated 12 Jun 2017

    There is a potential risk that could cause unintended flow in the older, centered sear door latch design in the Alaris Pump module model 8100.

    • Terminated Z-0950-2017 FDA Class I initiated 2 Dec 2016

    During an infusion, a false Air-in-Line (AIL) alarm would cause the infusion to be interrupted.

    • Terminated Z-1567-2014 FDA Class I initiated 23 Apr 2014

    CareFusion is recalling the Alaris Pump model 8100 version 9.1.18 because it may have a software issue that results in situation where the pump module will not properly delay an infusion when the "Delay Until" option or "Multidose" feature is used.

    • Terminated Z-2185-2012 FDA Class I initiated 29 Jun 2012

    The recall was initiated because Carefusion identified a potential risk associated with the Alaris Pump module model 8100. Carefusion has received reports of customers experiencing motor stalls during infusion with Alaris Pump Module (model 8100) manufactured between August 2010 and July 2011.

    • Terminated Z-2205-2012 FDA Class I initiated 15 Jun 2012

    The recall was initiated because Carefusion has identified a potential risk associated with the Alaris Pump module model 8100. The pump module door keypad overlay may separate from the keypad assembly

    • Terminated Z-1793-2009 FDA Unclassified (pre-2012) initiated 12 Jun 2009

    There is a potential risk of over infusion when certain fluids solidify in the pumping mechanism of the Alaris Pump module. This notification is to reinforce the importance of proper techniques for IV set loading and cleaning. When IV sets are improperly loaded, the set can tear and cause medication to leak and potentially enter the bezel area. Improper cleaning of the device, such as using hig

    • Terminated Z-1794-2009 FDA Unclassified (pre-2012) initiated 12 Jun 2009

    There is a potential risk of IUI connector failure in the Alaris System when these connectors become corroded or contaminated, which may result in an interruption of infusion with an audible and visual alarm. IUI connectors can become corroded or contaminated when exposed to fluid spills or improper cleaning. This notification is to reinforce the importance of inspection of IUI connectors prior

    • Terminated Z-1712-2008 FDA Unclassified (pre-2012) initiated 5 Mar 2008

    A channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors due to failure of the U9 Socketed Integrated Circuits (U9 IC) on the display board of the Alaris Syringe Module ("Syringe module") and Alaris PCA module ("PCA module") for modules manufactured on or before October 4, 2005. The user will be required to re

    • Terminated Z-1710-2008 FDA Unclassified (pre-2012) initiated 5 Mar 2008

    A channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors due to failures of the U19 Socketed Integrated Circuits (U19 IC) on the logic board of the Alaris Pump module ("Pump module"). The user will be required to replace the affected module.

    • Terminated Z-1711-2008 FDA Unclassified (pre-2012) initiated 5 Mar 2008

    A channel error on an affected Alaris System module will stop an active infusion (or monitoring) with an audible and visual alarm. Channel errors with the Alaris System due to the Inter-Unit Interface (IUI) connectors on all Alaris System modules (manufactured on or before March 26, 2004). Grey Inter-Unit Interface Connectors ("IUI") on the following Alaris System modules built on or before March

    • Terminated Z-0568-05 FDA Unclassified (pre-2012) initiated 10 Nov 2004

    The device modification is being implemented in response to information received from the field regarding a specific method of misloading the medication administration tubing set into the infusion system pump module. To date there have been complaints from three (3) different customer locations.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
FRN
Device Class
Class II
Regulation
21 CFR Part 880.5725
Advisory Committee
General Hospital
FDA Decision
SESE Substantially Equivalent

Other devices from Imed Corp.

See all devices from Imed Corp. →