Three-Lumen CVC for use only with Arrow MAC(TM) Two-Lumen Central Venous Access Device
by Arrow International LLC (Subsidiary of Teleflex Incorporated)
Ref ML-00703
Active
Valid until
Not listed
FDA recalls
1 ongoingDocuments
None linked in EUDAMED
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing GUDID | Number10801902189452 | Date1 Aug 2026 | StatusListed |
| European Union | CE/MDR EUDAMED | Number08019020000000000000042K8 10801902189452 | Date26 May 2026 | StatusActive |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
-
- Ongoing Z-2377-2026
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
-
- Terminated Z-1118-2019
- Terminated Z-1119-2019
The product lidstock contains a labelling error. The lidstock states the incorrect priming volume. The priming volumes printed on the extension lines are correct
-
- Terminated Z-0723-2019
The lidstock states the incorrect priming volume and flow rates.
-
- Terminated Z-2819-2018
- Terminated Z-2818-2018
The packaging may not be sealed. If the packaging is compromised in this manner, the sterility of the product cannot be guaranteed.
-
- Terminated Z-2336-2018
The recalling firm has received complaints related to increased resistance encountered when introducing the CVC over the spring wire guide. This may lead to procedural delay, and there may be need of medical intervention by exchanging the catheter for another CVC catheter.
-
- Terminated Z-1982-2018
- Terminated Z-1967-2018
- Terminated Z-1978-2018
Product sterility may be compromised due to unsealed packaging.
-
- Terminated Z-1332-2018
Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed.
-
- Terminated Z-0650-2018
- Terminated Z-0657-2018
- Terminated Z-0648-2018
- Terminated Z-0654-2018
- Terminated Z-0652-2018
These finished good kits may contain the incorrect Springwire Guide (SWG).
-
- Terminated Z-2336-2017
The Arrow CVC is indicated to provide short-term (<30 days) central venous access for treatment of diseases or conditions requiring central venous access including, but not limited to: -multiple infusions of fluids, medications, or chemotherapy -infusion of fluids that are hypertonic, hyperosmolar, or have divergent pH values -frequent blood sampling or blood/blood components infusions -infusion of incompatible medications -central venous pressure monitoring lack of usable peripheral IV sites -replacement of multiple peripheral sites for IV access
-
- Terminated Z-0076-2015
Arrow International, Inc. has initiated a voluntary recall for product code AK- 12703, lot number RF3039028 because the label on the outer corrugate is labeled with the incorrect expiration date. All kits packaged within the corrugate are correctly labeled. There is no risk to the patient as the kits within the corrugate are labeled with the correct expiration date.
-
- Terminated Z-0066-2015
The component supplier recalled their 0.9% Sodium Chloride Injection USP BD Posiflush SF Saline Flush Syringe 10mL because some unit packages may exhibit open seals which impact package integrity and potentially product sterility.
-
- Terminated Z-1965-2013
Arrow is recalling the product due to a labeling inconsistency. One portion of the lidstock states the kit contains a 3-Lumen catheter while the rest of the lidstock correctly identifies the catheter as 2-Lumen.
-
- Terminated Z-0898-2011
One lot of product was inadvertently mislabeled with a product lidstock identifying the product as a triple-lumen catheter with product number CV-15703, but a double-lumen catheter with part number CV-16702 was actually packaged in the kit.
-
- Terminated Z-1653-2009
The spring wire guide is too large in diameter to pass through the needle, dilator and catheter.
-
- Terminated Z-1495-2009
Leakage: Material not lipid resistant, may crack and/or leak. Use of this device with lipid containing solutions or 70% isopropyl alcohol may cause leakage or air embolism.
-
- Terminated Z-0083-04
wrong product in box
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- Three-Lumen CVC for use only with Arrow MAC(TM) Two-Lumen Central Venous Access Device EUDAMEDArrow GUDID
- Generic Name
- Centrally-inserted central venous catheter
- Device Name
- Central Venous Catheter (CVC) Product
- Model / Ref / Catalog
- ML-00703, IPN919644
- Primary DI / UDI-DI
- 10801902189452
- Basic UDI-DI
- 08019020000000000000042K8
- 510(k) Number
- FDA Product Code
- DQY
- EMDN Code
- C01020203 Central venous multi-lumen (>2) catheters, non-tunneled
- GMDN Term
- Centrally-inserted central venous catheter
- Device Class
- Class III EUDAMEDClass II GUDID
- Regulation Number
- 870.1250
- Medical Purpose
- The Arrow catheter is indicated to permit short-term (< 30 day) central venous access for the treatment of diseases or conditions requiring central venous access, including, but not limited to the following: Lack of usable peripheral IV sites Central venous pressure monitoring Total parenteral nutrition (TPN) Infusions of fluids, medications, or chemotherapy Frequent blood sampling or receiving blood transfusions/blood products Injection of contrast media When used for pressure injection of contrast media, do not exceed the maximum indicated flow rate for each catheter lumen. The maximum pressure of power injector equipment used with the pressure injectable CVC may not exceed 400 psi.
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / Reference | ML-00703 | IPN919644 |
| Device Class | Class III | Class II |
Manufacturer details
- EUDAMED SRN
- US-PR-000023158
Other devices from Arrow International LLC (Subsidiary of Teleflex Incorporated)
See all devices from Arrow International LLC (Subsidiary of Teleflex Incorporated) →
Properties
Other properties (7)
- Contains Latex: No
- Prescription Use: No
- Over-the-Counter: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No