Skip to content

Tiger 206-70-110

by Trilliant Surgical, LLC

Tiger 206-70-110 is a medical device (FDA Class II; FDA product code HWC, Screw, Fixation, Bone) made by Trilliant Surgical, LLC, cleared under FDA 510(k) K153338 on 14 Jan 2016 and listed in FDA GUDID since 31 Jan 2017 (UDI-DI 00812926024547), active as of 8 Nov 2026. 4 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

4 closed

Documents

510(k) K153338

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 8 Nov 2026.

Regulatory status

as of registry sync 8 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00812926024547 UDI-DI Date31 Jan 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK153338 Date14 Jan 2016DecidedStatusActive

Official records

From the FDA record

Device description
7.0mm x 110mm LTTCS
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 8 Nov 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K153338 decided 14 Jan 2016 Active
  • FDA GUDID UDI-DI 00812926024547 listed 31 Jan 2017 Listed

Recalls

4 recalls · FDA

  • 3 recalls, same reason

    • Terminated Z-1605-2020 FDA Class II initiated 19 Jul 2018
    • Terminated Z-1606-2020 FDA Class II initiated 19 Jul 2018
    • Terminated Z-1612-2020 FDA Class II initiated 19 Jul 2018

    Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

    • Terminated Z-0960-2017 FDA Class II initiated 8 Dec 2016

    Four lots of Tiger Screw Sterilization Tray Base Assemblies were released to the field with a printing error where k-wire description markings indicate diameters of 0.45 and 0.35 instead of 0.045" and 0.035", respectively.

Timeline

6 dated events

  1. Cleared FDA 510(k) K153338
  2. Recall initiated FDA recalls Z-0960-2017
  3. Listed FDA GUDID 00812926024547
  4. Recall initiated FDA recalls Z-1605-2020
  5. Recall initiated FDA recalls Z-1606-2020
  6. Recall initiated FDA recalls Z-1612-2020

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Tiger
Generic name
Orthopaedic bone screw (non-sliding)
Model / reference
206-70-110
Primary DI / UDI-DI
00812926024547
510(k) Number
FDA product code
HWC
GMDN term
Orthopaedic bone screw (non-sliding)
Device class
Class II
Regulation number
888.3040
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Unsafe

Similar devices in this category

Other devices filed under Orthopaedic bone screw (non-sliding).

Other devices from Trilliant Surgical, LLC

See all devices from Trilliant Surgical, LLC →

Properties

  • Sterilise before use
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
Other properties (10, all answered No)