Skip to content

Titanium Mittelmeier Type Acetabular

by American Ortomed Corp.

510(k) K842466

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK842466 Date30 Jan 1985ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
KWA
Device Class
Class III
Regulation
21 CFR Part 888.3330
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Titanium Mittelmeier Type Acetabular is a semi-constrained metal uncemented acetabular component for the hip, designed as a prosthetic replacement. It is intended for use in total hip arthroplasty procedures, providing a stable acetabular cup interface for load-bearing and articulation with femoral components.

This device is supplied as a reusable surgical implant, intended for use in controlled clinical settings such as orthopedic operating rooms. It is manufactured from titanium and does not require sterilization prior to use, as it is intended for single-patient implantation. The device is classified under FDA regulation number 888.3330 and holds a 510(k) clearance (K842466) as substantially equivalent to a predicate device. Multiple registration numbers and FEI numbers are associated with its distribution and tracking.

Other devices from American Ortomed Corp.

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of hip procedures is the Titanium Mittelmeier Type Acetabular designed for, and how does it function in those procedures?

    The Titanium Mittelmeier Type Acetabular is specifically designed for total hip arthroplasty procedures, serving as a prosthetic replacement for the acetabulum. It is a semi-constrained, metal, uncemented acetabular component, meaning it is intended to articulate with femoral components while providing stability without the need for bone cement. Its uncemented design relies on osseointegration with the patient’s bone over time, making it suitable for primary or revision hip replacements where a secure, load-bearing interface is required.

  • Is this device intended for single-use or can it be reused in multiple patients?

    The Titanium Mittelmeier Type Acetabular is explicitly intended for single-patient implantation only. While it is manufactured as a reusable surgical implant, its design and regulatory classification (as a prosthetic device) dictate that it must remain sterile and dedicated to one patient per use, adhering to standard orthopedic implant protocols to prevent cross-contamination and ensure patient safety.

  • What materials is the device made from, and does it require sterilization before use?

    The device is manufactured entirely from titanium, a biocompatible metal commonly used in orthopedic implants for its strength and corrosion resistance. Since it is intended for single-patient use, sterilization is not required prior to implantation—it is supplied in a sterile condition ready for surgical use, as outlined in its design and regulatory documentation.

  • How is the device tracked or identified for regulatory and inventory purposes?

    The Titanium Mittelmeier Type Acetabular is associated with multiple FEI numbers (e.g., 3020282716, 3007923096) and registration numbers (e.g., 8043792) for tracking and distribution. These identifiers are used by regulatory bodies and distributors to monitor its supply chain, compliance, and recall processes. The device’s product code (KWA) and FDA classification (888.3330) further categorize it for administrative and inventory management.

  • What should clinicians consider when storing or handling this device before surgery?

    Since the device is sterile and single-use, clinicians should store it in a controlled, sterile environment (e.g., a sterile tray or packaging) until immediately before use to maintain its integrity. The titanium construction means it is resistant to corrosion, but it should be handled with care to avoid scratches or damage that could compromise its performance. Always follow manufacturer guidelines for unpacking and preparation to ensure sterility and readiness for implantation.