Skip to content

Titanium Screws 1

by Orthofix SRL

Ref T10110Model BONE FIXATION SCREWS, TENDONS AND LIGAMENTS SCREWS

Titanium Screws 1 (T10110) is an orthopaedic bone screw (EU MDR Class IIb; FDA Class II; FDA product code JDW, Pin, Fixation, Threaded) made by Orthofix SRL, registered in EUDAMED on 22 Oct 2026 (Basic UDI-DI 805050436Screw2bNAC26B3K), cleared under FDA 510(k) K955848 on 20 Mar 1996 and listed in FDA GUDID since 16 Sep 2016 (UDI-DI 18032568865110), active as of 12 Nov 2026. 23 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

23 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K955848

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number805050436Screw2bNAC26B3K Basic UDI-DI 18032568865110UDI-DIDate22 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number18032568865110 UDI-DI Date16 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK955848 Date20 Mar 1996DecidedStatusActive

Official records

From the FDA record

Device description
TITANIUM CORTICAL SCREW LENGTH 110/30 MM
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 805050436Screw2bNAC26B3K registered 22 Oct 2026 Active
  • FDA 510(k) K955848 decided 20 Mar 1996 Active
  • FDA GUDID UDI-DI 18032568865110 listed 16 Sep 2016 Listed

Recalls

23 recalls · FDA

  • 21 recalls, same reason

    • Terminated Z-0373-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0374-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0375-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0376-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0377-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0378-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0379-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0380-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0381-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0382-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0383-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0384-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0385-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0386-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0387-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0388-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0389-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0390-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0391-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0392-2020 FDA Class II initiated 27 Sep 2018
    • Terminated Z-0393-2020 FDA Class II initiated 27 Sep 2018

    As a result of complaint investigations it was determined that batches of drill bits have a geometrical detail that does not correspond to the intended design. This could result in lower cutting performance.

  • 2 recalls, same reason

    • Terminated Z-1434-2010 FDA Unclassified (pre-2012) initiated 22 Feb 2010
    • Terminated Z-1435-2010 FDA Unclassified (pre-2012) initiated 22 Feb 2010

    During standard quality controls, firm identified a potential for breakage of the XCaliber clamp when locking the cam.

Timeline

26 dated events

  1. Recall initiated FDA recalls Z-0385-2020
  2. Recall initiated FDA recalls Z-0386-2020
  3. Recall initiated FDA recalls Z-0387-2020
  4. Recall initiated FDA recalls Z-0388-2020
  5. Recall initiated FDA recalls Z-0389-2020
  6. Recall initiated FDA recalls Z-0390-2020
  7. Recall initiated FDA recalls Z-0391-2020
  8. Recall initiated FDA recalls Z-0392-2020
  9. Recall initiated FDA recalls Z-0393-2020
  10. Registered EUDAMED 805050436Screw2bNAC26B3K

16 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Implantable Devices for External Fixation and Related Instruments EUDAMED
Titanium Screws GUDID
Generic name
Orthopaedic bone screw, non-bioabsorbable, non-sterile
Model / Ref / Catalog
BONE FIXATION SCREWS, TENDONS AND LIGAMENTS SCREWS, T10110, 1
Primary DI / UDI-DI
18032568865110
Basic UDI-DI
805050436Screw2bNAC26B3K
510(k) Number
FDA product code
JDW
EMDN code
P09120402 Screws
GMDN term
Orthopaedic bone screw, non-bioabsorbable, non-sterile
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
888.3040
EU registration type
Standard device
EU market of registration
Italy
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
Size
Length — 110 Millimeter

Truth per registry

2 sources · 3 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
BONE FIXATION SCREWS, TENDONS AND LIGAMENTS SCREWS
T10110
GUDID
1
Device classEUDAMED
Class IIb
GUDID
Class II
ImplantableEUDAMED
Yes
GUDID
No

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under SCREWS.

Other devices from Orthofix SRL

See all devices from Orthofix SRL →

Properties

  • Sterilise before use
  • Single use
  • Implantable YesEUDAMEDNoGUDID
  • Sutures
  • Prescription use
  • Lot / batch number
  • Serial number
  • Manufacturing date
Other properties (18, all answered No)