Skip to content

TMS System 25-6207

by Biomet Microfixation, Inc

Ref 25-6207

TMS System 25-6207 is an orthopaedic bone screw (EU MDD Class IIb; FDA Class II) made by Biomet Microfixation, Inc, registered in EUDAMED on 23 Oct 2026 (Basic UDI-DI B-00841036089214), cleared under FDA 510(k) K121624 on 12 Oct 2012 (2 earlier submissions) and listed in FDA GUDID since 11 Oct 2015 (UDI-DI 00841036089214), active as of 7 Nov 2026. 3 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

3 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00841036089214 Basic UDI-DI 00841036089214UDI-DIDate23 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00841036089214 UDI-DI Date11 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK121624 Date12 Oct 2012DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00841036089214 registered 23 Oct 2026 Active
  • FDA 510(k) K121624 decided 12 Oct 2012 Active· +2 more in the status table
  • FDA GUDID UDI-DI 00841036089214 listed 11 Oct 2015 Listed

Recalls

3 recalls · FDA

    • Terminated Z-1220-2017 FDA Class II initiated 10 Jan 2017

    The identification of the devices was non-conforming with off-centered slots and the no-go gage starting in the pilot hole.

  • 2 recalls, same reason

    • Terminated Z-0137-2016 FDA Class II initiated 6 Aug 2015
    • Terminated Z-0136-2016 FDA Class II initiated 6 Aug 2015

    The lids on implant caddies within P/N 17-5000 and 19-5000 could not be opened by the user without application of undesirable/unexpected excessive force.

Timeline

8 dated events

  1. Cleared FDA 510(k) K013954
  2. Cleared FDA 510(k) K121589
  3. Cleared FDA 510(k) K121624
  4. Recall initiated FDA recalls Z-0137-2016
  5. Recall initiated FDA recalls Z-0136-2016
  6. Listed FDA GUDID 00841036089214
  7. Recall initiated FDA recalls Z-1220-2017
  8. Registered EUDAMED B-00841036089214

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Tms System
Generic name
Orthopaedic bone screw, non-bioabsorbable, non-sterile
Model / Ref / Catalog
25-6207
Primary DI / UDI-DI
00841036089214
Basic UDI-DI
B-00841036089214
FDA product code
GXR, HBW, GWO, JEY, HWC
EMDN code
P09120503 Osteosynthesis screw-plate systems
GMDN term
Orthopaedic bone screw, non-bioabsorbable, non-sterile
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
882.5250, 882.5360, 882.5320, 872.4760, 888.3040
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II
ImplantableEUDAMED
Yes
GUDID
No

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under OSTEOSYNTHESIS SCREW-PLATE SYSTEMS.

Other devices from Biomet Microfixation, Inc

See all devices from Biomet Microfixation, Inc →

Properties

  • Sterilise before use
  • Single use
  • Implantable YesEUDAMEDNoGUDID
  • Prescription use
  • Lot / batch number
Other properties (20, all answered No)