Transonic HQD2FMC
by Transonic Systems Inc. 2 variants
Transonic HQD2FMC is an invasive vascular ultrasound system (FDA Class II; FDA product code DPW, Flowmeter, Blood, Cardiovascular) made by Transonic Systems Inc., cleared under FDA 510(k) K872048 on 21 Jun 1988 and listed in FDA GUDID since 8 Oct 2020 (UDI-DI 00877466001571), active as of 23 Oct 2026. 10 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00877466001571 | Date8 Oct 2020 | StatusListed |
| United States | FDA 510(k)SESE | NumberK872048 | Date21 Jun 1988 | StatusActive |
Official records
- AccessGUDID record 00877466001571
- FDA 510(k) database K872048
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use
Across registries
- FDA 510(k) K872048 decided 21 Jun 1988 Active
- FDA GUDID UDI-DI 00877466001571 listed 8 Oct 2020 Listed
Recalls
-
- Terminated Z-2724-2015
- Terminated Z-2727-2015
- Terminated Z-2723-2015
- Terminated Z-2720-2015
- Terminated Z-2725-2015
- Terminated Z-2729-2015
- Terminated Z-2722-2015
- Terminated Z-2726-2015
- Terminated Z-2721-2015
- Terminated Z-2728-2015
Software defect; programming errors in the blood flow probes EPROM. Transonic received several complaints from users indicating that when the flow probe is connected to a flow meter the meter reads Used Probe or Irrelevant Use Number.
Timeline
- Recall initiated FDA recalls Z-2727-2015
- Recall initiated FDA recalls Z-2723-2015
- Recall initiated FDA recalls Z-2720-2015
- Recall initiated FDA recalls Z-2725-2015
- Recall initiated FDA recalls Z-2729-2015
- Recall initiated FDA recalls Z-2722-2015
- Recall initiated FDA recalls Z-2726-2015
- Recall initiated FDA recalls Z-2721-2015
- Recall initiated FDA recalls Z-2728-2015
- Listed FDA GUDID 00877466001571
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Transonic
- Generic name
- Invasive vascular ultrasound system
- Model / reference
- HQD2FMC
- Primary DI / UDI-DI
- 00877466001571
- 510(k) Number
- FDA product code
- DPW
- GMDN term
- Invasive vascular ultrasound system
- Device class
- Class II
- Regulation number
- 870.2100
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code DPW (Flowmeter, Blood, Cardiovascular).
- Bidop 7 by Koven Technology, Inc.
- VTI 8MHz TQI 2.0 Doppler Transceiver 108850 by VASCULAR TECHNOLOGY, INCORPORATED
- LV-20 VOLUMETER, 20 MHZ DOPPLER BLOOD FLOW METER by Titronics Medical Instruments, Inc.
- DELTEX MEDICAL CARDIOQ-EDM+ by Deltex Medical
- VascuChek Kit, VascuChek Transceiver, VascuChek Clinical Probe, VascuChek Charger by REMINGTON MEDICAL, INC.
- WRIGHT POCKET DOPPLERS VASCULAR & OBSTETRIC by Wright Medical
- Ultrasonic Pocket Doppler SD3 PRO by Edan Instruments,Inc.
- TISSUE SPECTROSCOPE by Vital Medical, Ltd.
- MODIF. LASERFLO BLOOD PERFUSION MONITOR MODEL BPM2 by Vasamedics, LLC
- MEDI-STIM VERIQ SYSTEM, MODEL VQ1001 - VQ4122 by Medi-Stim A/S