Skip to content

Transvenous Balloon Tipped(Flow Directed) Temp. Pa

by Mansfield Scientific, Inc.

510(k) K844752

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK844752 Date2 Jan 1985ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Transvenous Balloon-Tipped (Flow Directed) Temporary Pulmonary Artery Catheter, classified under the nomenclature for Permanent Pacemaker Electrode (OpenFDA DTB: 300xx series). It is designed for temporary hemodynamic monitoring, specifically to measure central venous pressure and pulmonary artery pressure via a balloon-tipped catheter advanced through the venous system into the pulmonary artery. The flow-directed design ensures accurate placement by following blood flow dynamics, reducing the need for fluoroscopic guidance in many cases.

The catheter is intended for use in clinical settings such as intensive care units (ICUs) and cardiac care units for short-term hemodynamic assessment. Supplied sterile and intended for single-use, it requires aseptic handling and proper disposal after use. Compliance with FDA 510(k) clearance (K844752) ensures adherence to regulatory standards for cardiovascular monitoring devices. No MRI safety information is specified, and storage should follow manufacturer guidelines for sterile, dry conditions.

Other devices from Mainsfield Scientific, Inc.

See all devices from Mainsfield Scientific, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical settings is this catheter primarily used in, and what does it measure?

    This device is designed for short-term hemodynamic monitoring in intensive care units (ICUs) and cardiac care units. It measures central venous pressure and pulmonary artery pressure by using a balloon-tipped, flow-directed design that follows blood flow dynamics for accurate placement, reducing reliance on fluoroscopy.

  • Is this catheter reusable or intended for single-use, and how should it be handled?

    The catheter is supplied sterile and intended for single-use only. Due to its sterile packaging, it requires aseptic handling during insertion and must be properly disposed of after use to maintain infection control standards.

  • Does this device require fluoroscopy for proper placement, and why?

    The flow-directed design of this catheter is engineered to follow natural blood flow dynamics, which often allows for accurate placement without fluoroscopy in many clinical scenarios. This reduces the need for X-ray guidance while still ensuring correct positioning in the pulmonary artery.

  • What storage conditions should be followed for this device?

    The manufacturer recommends storing this catheter in sterile, dry conditions as specified in their guidelines. Since it is supplied sterile and single-use, it should remain unopened until ready for immediate clinical use to preserve sterility.

  • What regulatory pathway does this device follow, and how does that affect its use?

    This device follows the FDA 510(k) clearance pathway (K844752) under the classification for permanent pacemaker electrodes (DTB 300xx series). The clearance ensures it meets U.S. regulatory standards for cardiovascular monitoring devices, though clinical use remains guided by physician judgment and institutional protocols.