Transvenous Balloon Tipped(Flow Directed) Temp. Pa
510(k) K844752
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK844752 | Date2 Jan 1985 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DTB
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3680
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
This device is a Transvenous Balloon-Tipped (Flow Directed) Temporary Pulmonary Artery Catheter, classified under the nomenclature for Permanent Pacemaker Electrode (OpenFDA DTB: 300xx series). It is designed for temporary hemodynamic monitoring, specifically to measure central venous pressure and pulmonary artery pressure via a balloon-tipped catheter advanced through the venous system into the pulmonary artery. The flow-directed design ensures accurate placement by following blood flow dynamics, reducing the need for fluoroscopic guidance in many cases.
The catheter is intended for use in clinical settings such as intensive care units (ICUs) and cardiac care units for short-term hemodynamic assessment. Supplied sterile and intended for single-use, it requires aseptic handling and proper disposal after use. Compliance with FDA 510(k) clearance (K844752) ensures adherence to regulatory standards for cardiovascular monitoring devices. No MRI safety information is specified, and storage should follow manufacturer guidelines for sterile, dry conditions.
Other devices from Mainsfield Scientific, Inc.
Questions
AI-generated answers, 18 Sep 2026
What clinical settings is this catheter primarily used in, and what does it measure?
This device is designed for short-term hemodynamic monitoring in intensive care units (ICUs) and cardiac care units. It measures central venous pressure and pulmonary artery pressure by using a balloon-tipped, flow-directed design that follows blood flow dynamics for accurate placement, reducing reliance on fluoroscopy.
Is this catheter reusable or intended for single-use, and how should it be handled?
The catheter is supplied sterile and intended for single-use only. Due to its sterile packaging, it requires aseptic handling during insertion and must be properly disposed of after use to maintain infection control standards.
Does this device require fluoroscopy for proper placement, and why?
The flow-directed design of this catheter is engineered to follow natural blood flow dynamics, which often allows for accurate placement without fluoroscopy in many clinical scenarios. This reduces the need for X-ray guidance while still ensuring correct positioning in the pulmonary artery.
What storage conditions should be followed for this device?
The manufacturer recommends storing this catheter in sterile, dry conditions as specified in their guidelines. Since it is supplied sterile and single-use, it should remain unopened until ready for immediate clinical use to preserve sterility.
What regulatory pathway does this device follow, and how does that affect its use?
This device follows the FDA 510(k) clearance pathway (K844752) under the classification for permanent pacemaker electrodes (DTB 300xx series). The clearance ensures it meets U.S. regulatory standards for cardiovascular monitoring devices, though clinical use remains guided by physician judgment and institutional protocols.