Skip to content

TraumaOne SYSTEM SP-2585

by Biomet Microfixation, Inc

Ref SP-2585

TraumaOne SYSTEM SP-2585 is a craniofacial fixation plate (EU MDD Class IIb; FDA Class II; FDA product code JEY, Plate, Bone) made by Biomet Microfixation, Inc, registered in EUDAMED on 23 Oct 2026 (Basic UDI-DI B-00888233017701), cleared under FDA 510(k) K121589 on 21 Sep 2012 (1 earlier submission) and listed in FDA GUDID since 16 Jun 2020 (UDI-DI 00888233017701), active as of 7 Nov 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00888233017701 Basic UDI-DI 00888233017701UDI-DIDate23 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00888233017701 UDI-DI Date16 Jun 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK121589 Date21 Sep 2012DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00888233017701 registered 23 Oct 2026 Active
  • FDA 510(k) K121589 decided 21 Sep 2012 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00888233017701 listed 16 Jun 2020 Listed

Recalls

1 recall · FDA

    • Terminated Z-1220-2017 FDA Class II initiated 10 Jan 2017 on shared 510(k) K121589

    The identification of the devices was non-conforming with off-centered slots and the no-go gage starting in the pilot hole.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Cleared FDA 510(k) K081067
  2. Cleared FDA 510(k) K121589
  3. Recall initiated FDA recalls Z-1220-2017
  4. Listed FDA GUDID 00888233017701
  5. Registered EUDAMED B-00888233017701

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
TraumaOne SYSTEM
Generic name
Craniofacial fixation plate, non-bioabsorbable, non-customized
Model / Ref / Catalog
SP-2585
Primary DI / UDI-DI
00888233017701
Basic UDI-DI
B-00888233017701
510(k) Number
FDA product code
JEY
EMDN code
P09120503 Osteosynthesis screw-plate systems
GMDN term
Craniofacial fixation plate, non-bioabsorbable, non-customized
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
872.4760
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under OSTEOSYNTHESIS SCREW-PLATE SYSTEMS.

Other devices from Biomet Microfixation, Inc

See all devices from Biomet Microfixation, Inc →

Properties

  • Sterilise before use
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
Other properties (20, all answered No)