Skip to content

Triathlon Total Knee System - Triathlon X3 Medial Stabilized Tibial Bearing Insert

by Howmedica Osteonics Corp., Dba Stryker Orthopaedics

510(k) K253637

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK253637 Date18 Feb 2026ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
MBH
Device Class
Class II
Regulation
21 CFR Part 888.3565
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Triathlon X3 Medial Stabilized Tibial Bearing Insert is a medial stabilized tibial bearing designed as a component of the Triathlon Total Knee System for total knee arthroplasty. It is classified as an orthopedic implant with an asymmetric articulating surface intended to enhance medial conformity with compatible femoral components. This insert is engineered to support primary or revision knee replacement procedures, improving joint stability and alignment. Its design emphasizes sagittal stability to optimize knee function post-implantation.

This device is supplied as a sterile, single-use implant and is intended for use in orthopedic surgical settings. It is part of the Triathlon Total Knee System, requiring compatible femoral components for proper function. The insert is regulated under FDA 510(k) clearance (K253637) and falls under the MBH product code for orthopedic knee prostheses. Storage and handling must adhere to sterile surgical protocols to maintain integrity before use.

Other devices from Howmedica Osteonics Corp., Dba Stryker Orthopaedics

See all devices from Howmedica Osteonics Corp., Dba Stryker Orthopaedics →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of knee replacement surgeries is the Triathlon X3 Medial Stabilized Tibial Bearing Insert designed for?

    The Triathlon X3 Medial Stabilized Tibial Bearing Insert is specifically designed for use in both primary and revision total knee arthroplasty procedures. Its asymmetric articulating surface and medial stabilization are engineered to enhance joint stability and alignment, making it suitable for surgeries where improved knee function and sagittal stability are priorities.

  • Is this tibial bearing insert compatible with all femoral components, or does it require specific pairing?

    This insert is part of the Triathlon Total Knee System and is intended for use only with compatible femoral components from the same system. The asymmetric design relies on matching geometry to ensure proper articulation and stability, so pairing with non-compatible femoral components could compromise performance.

  • How should the Triathlon X3 Medial Stabilized Tibial Bearing Insert be stored and handled before use?

    As a sterile, single-use implant, the insert must be stored and handled according to standard sterile surgical protocols to preserve its integrity. This includes maintaining sealed packaging until immediate preoperative use and adhering to manufacturer guidelines for temperature and humidity control to prevent contamination or degradation.

  • What distinguishes the medial stabilization feature of this tibial bearing insert?

    The medial stabilization feature of the Triathlon X3 insert is designed to improve conformity between the tibial plateau and femoral component on the medial side of the knee. This asymmetric articulating surface helps reduce stress concentrations and enhances stability during flexion and extension, particularly for patients requiring precise alignment in total knee replacements.

  • Is this device regulated under a specific FDA pathway, and what does that mean for its use?

    The Triathlon X3 Medial Stabilized Tibial Bearing Insert is cleared under the FDA’s 510(k) pathway (K253637) with a determination of *Substantially Equivalent* to a predicate device. This means it has been evaluated by the FDA Orthopedic (OR) Advisory Committee and deemed comparable in safety and effectiveness to an existing orthopedic knee prosthesis, allowing for its use in clinical settings where total knee arthroplasty is performed.