Trident, Rio 209830
Ref 209830Model 08858251002220S2
Trident, Rio 209830 is an orthopaedic implant impactor (EU MDR Class IIa; FDA Class II; FDA product code OLO, Orthopedic stereotaxic instrument) made by MAKO Surgical Corp., registered in EUDAMED on 12 Oct 2026 (Basic UDI-DI 08858251002220S2), cleared under FDA 510(k) K170593 on 18 Apr 2017 (1 earlier submission) and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 00848486030285), active as of 23 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number08858251002220S2 00848486030285 | Date12 Oct 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK170593 | Date18 Apr 2017 | StatusActive |
| United States | GUDID listing GUDID | Number00848486030285 | Date24 Sep 2016 | StatusListed |
Official records
- EUDAMED public site 08858251002220S2
- AccessGUDID record 00848486030285
- FDA 510(k) database K170593
- FDA 510(k) database K141989
From the FDA record
- Device description
- INLINE-OFFSET SHELL IMPACTOR
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 08858251002220S2 registered 12 Oct 2026 Active
- FDA 510(k) K170593 decided 18 Apr 2017 Active
- FDA GUDID UDI-DI 00848486030285 listed 24 Sep 2016 Listed
Recalls
-
- Terminated Z-2745-2020
Characterization issue associated with the product. This issue may cause a discrepancy during bone preparation in certain Mako Total Hip procedures.
-
- Terminated Z-3182-2018
Communication-connection error.
-
- Terminated Z-3131-2017
Software discrepancy of not showing all the EE constants, when the screen is filled.
-
- Terminated Z-1411-2017
Five (5) AFMEA Risk Control Measures are missing from the MAKO RIO THA Application User Guides
Timeline
- Cleared FDA 510(k) K141989
- Listed FDA GUDID 00848486030285
- Recall initiated FDA recalls Z-1411-2017
- Cleared FDA 510(k) K170593
- Recall initiated FDA recalls Z-3131-2017
- Recall initiated FDA recalls Z-3182-2018
- Recall initiated FDA recalls Z-2745-2020
- Registered EUDAMED 08858251002220S2
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Mako EUDAMEDTrident, Rio GUDID
- Generic name
- Orthopaedic implant impactor, reusable
- Device name
- TD-01 - MAKO - Class IIa - Shell Impactor
- Model / Ref / Catalog
- 209830, 08858251002220S2
- Primary DI / UDI-DI
- 00848486030285
- Basic UDI-DI
- 08858251002220S2
- Direct marketing DI
- 00848486030285
- FDA product code
- OLO
- EMDN code
- L091199 Orthopaedic prosthetics instruments, reusable - other
- GMDN term
- Orthopaedic implant impactor, reusable
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 882.4560
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under ORTHOPAEDIC PROSTHETICS INSTRUMENTS, REUSABLE - OTHER.
- U-Motion II 9206-1102 by UNITED ORTHOPEDIC CORP.
- Aesculap ND017R by Aesculap AG
- U2 Total Knee System 2303-2424-RF by UNITED ORTHOPEDIC CORP.
- SQ.line® ND005NR by Aesculap AG
- DIAM, Bi-Lateral Impactor CS001B0025 by Companion Spine France
- USTAR II Knee System 2915-2110 by United Orthopedic Corporation
- Instrument Box CS100501 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- Slap Hammer II-1-0005 by Integrity Implants Inc.
- NexGen® 5989-01-27 00-5989-001-27 by Zimmer, Inc.
- Measuring Device C65001 by Tianjin Zhengtian Medical Instrument Co., Ltd.