Trigen 71675040
Trigen 71675040 is a Class II device made by Smith & Nephew, Inc., cleared under FDA 510(k) K210980 on 14 Nov 2022 (1 earlier submission) and listed in FDA GUDID since 13 Nov 2017 (UDI-DI 03596010524720), active as of 23 Oct 2026. 6 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
6 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK210980 | Date14 Nov 2022 | StatusActive |
| United States | GUDID listing | Number03596010524720 | Date13 Nov 2017 | StatusListed |
Official records
- AccessGUDID record 03596010524720
- FDA 510(k) database K210980
- FDA 510(k) database K040212
Across registries
- FDA 510(k) K210980 decided 14 Nov 2022 Active
- FDA GUDID UDI-DI 03596010524720 listed 13 Nov 2017 Listed
Recalls
-
- Ongoing Z-2456-2026
Humeral nail due to a manufacturing error is missing distal holes and if implanted may lead to revision surgery but, if the missing holes are identified before implantation, an equivalent backup can be used, or a bent nail of the same size, which would require additional surgical steps to address soft tissue/bone preparation, which could lead to a surgical delay of greater than 30 minutes.
-
- Ongoing Z-1806-2025
Integrated Lag/Compression Screw Kit has a compression screw with hexagon socket that may be undersized, which causes the screw to be non-functional, which would require replacement with another adequate size screw, and exchange may exceed 30 minutes.
-
- Ongoing Z-2443-2023
- Ongoing Z-2444-2023
A complaint was received indicating that a package contained a TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 40CM 130 DEGREE LEFT implant instead of a TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 36CM 130 DEGREE LEFT as described on the product label.
-
- Ongoing Z-1133-2022
Right nails were anodized, marked, and labelled as left nails and vice versa
-
- Ongoing Z-0097-2018
A single lot of INTERTAN 10S 10 MM X 18 CM 130 D was manufactured with the screw inserted upside down.
-
- Terminated Z-0772-2021
Manufacturing packaging error.
-
- Terminated Z-2258-2014
There was an error in manufacturing which resulted in the proximal lag screw hole being positioned incorrectly in several batches of TRIGEN(R); INTERTAN(TM); NAILS.
-
- Terminated Z-1637-2014
- Terminated Z-1636-2014
A manufacturing error resulted in the set screw being inserted too deep in the affected nails.
Timeline
- Recall initiated FDA recalls Z-2258-2014
- Recall initiated FDA recalls Z-0097-2018
- Listed FDA GUDID 03596010524720
- Recall initiated FDA recalls Z-0772-2021
- Recall initiated FDA recalls Z-1133-2022
- Cleared FDA 510(k) K210980
- Recall initiated FDA recalls Z-2443-2023
- Recall initiated FDA recalls Z-2444-2023
- Recall initiated FDA recalls Z-1806-2025
- Recall initiated FDA recalls Z-2456-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Trigen
- Generic name
- Bone nail implantable cap
- Model / Ref / Catalog
- 71675040
- Primary DI / UDI-DI
- 03596010524720
- FDA product code
- JDS
- GMDN term
- Bone nail implantable cap
- Device class
- Class II
- Regulation number
- 888.3030
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional