Skip to content

Trigen 71675040

by Smith & Nephew, Inc.

Trigen 71675040 is a Class II device made by Smith & Nephew, Inc., cleared under FDA 510(k) K210980 on 14 Nov 2022 (1 earlier submission) and listed in FDA GUDID since 13 Nov 2017 (UDI-DI 03596010524720), active as of 23 Oct 2026. 6 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

6 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK210980 Date14 Nov 2022DecidedStatusActive
United StatesGUDID listing Number03596010524720 UDI-DI Date13 Nov 2017ListedStatusListed GUDID: in commercial distribution

Official records

Across registries

2 registries list this device

  • FDA 510(k) K210980 decided 14 Nov 2022 Active· +1 more in the status table
  • FDA GUDID UDI-DI 03596010524720 listed 13 Nov 2017 Listed

Recalls

10 recalls · 6 ongoing · FDA

    • Ongoing Z-2456-2026 FDA Class II initiated 16 Mar 2026 on shared 510(k) K210980

    Humeral nail due to a manufacturing error is missing distal holes and if implanted may lead to revision surgery but, if the missing holes are identified before implantation, an equivalent backup can be used, or a bent nail of the same size, which would require additional surgical steps to address soft tissue/bone preparation, which could lead to a surgical delay of greater than 30 minutes.

    • Ongoing Z-1806-2025 FDA Class II initiated 18 Mar 2025 on shared 510(k) K210980

    Integrated Lag/Compression Screw Kit has a compression screw with hexagon socket that may be undersized, which causes the screw to be non-functional, which would require replacement with another adequate size screw, and exchange may exceed 30 minutes.

  • 2 recalls, same reason

    • Ongoing Z-2443-2023 FDA Class II initiated 24 Jul 2023 on shared 510(k) K210980
    • Ongoing Z-2444-2023 FDA Class II initiated 24 Jul 2023 on shared 510(k) K210980

    A complaint was received indicating that a package contained a TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 40CM 130 DEGREE LEFT implant instead of a TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 36CM 130 DEGREE LEFT as described on the product label.

    • Ongoing Z-1133-2022 FDA Class II initiated 22 Apr 2022

    Right nails were anodized, marked, and labelled as left nails and vice versa

    • Ongoing Z-0097-2018 FDA Class II initiated 24 Oct 2017

    A single lot of INTERTAN 10S 10 MM X 18 CM 130 D was manufactured with the screw inserted upside down.

    • Terminated Z-0772-2021 FDA Class II initiated 2 Nov 2020

    Manufacturing packaging error.

    • Terminated Z-2258-2014 FDA Class II initiated 2 Jul 2014

    There was an error in manufacturing which resulted in the proximal lag screw hole being positioned incorrectly in several batches of TRIGEN(R); INTERTAN(TM); NAILS.

  • 2 recalls, same reason

    • Terminated Z-1637-2014 FDA Class II initiated 4 Apr 2014
    • Terminated Z-1636-2014 FDA Class II initiated 4 Apr 2014

    A manufacturing error resulted in the set screw being inserted too deep in the affected nails.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

13 dated events

  1. Recall initiated FDA recalls Z-2258-2014
  2. Recall initiated FDA recalls Z-0097-2018
  3. Listed FDA GUDID 03596010524720
  4. Recall initiated FDA recalls Z-0772-2021
  5. Recall initiated FDA recalls Z-1133-2022
  6. Cleared FDA 510(k) K210980
  7. Recall initiated FDA recalls Z-2443-2023
  8. Recall initiated FDA recalls Z-2444-2023
  9. Recall initiated FDA recalls Z-1806-2025
  10. Recall initiated FDA recalls Z-2456-2026

3 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Trigen
Generic name
Bone nail implantable cap
Model / Ref / Catalog
71675040
Primary DI / UDI-DI
03596010524720
510(k) Number
FDA product code
JDS
GMDN term
Bone nail implantable cap
Device class
Class II
Regulation number
888.3030
GUDID distribution status
In Commercial Distribution
MRI safety
MR Conditional

Other devices from Smith & Nephew, Inc.

See all devices from Smith & Nephew, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)