Trilogy 200 Trilogy200 Ventilator, Korea (Philips)
Trilogy 200 Trilogy200 Ventilator, Korea (Philips) (KO1032800), a portable electric ventilator (FDA Class II) made by Respironics Inc., was cleared under FDA 510(k) K093416 on 29 Jan 2010 and listed in FDA GUDID on 22 Sep 2017 (UDI-DI 00606959047419); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 5.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00606959047419 | Date22 Sep 2017 | StatusListed |
| United States | FDA 510(k)SESE | NumberK093416 | Date29 Jan 2010 | StatusActive |
Official records
- AccessGUDID record 00606959047419
- FDA 510(k) database K093416
From the FDA record
- Device description
- Trilogy 200 Ventilator, Korea
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K093416 decided 29 Jan 2010 Active
- FDA GUDID UDI-DI 00606959047419 listed 22 Sep 2017 Listed
Recalls
-
- Ongoing Z-0883-2023
The replacement silicone sound abatement foam installed into some Trilogy 100 and Trilogy 200 devices may separate from the plastic backing to which it is attached. If this were to happen, the foam could potentially block air inlet, which could result in a reduction in delivered therapy volume or pressure and could cause the device to alarm.
-
- Ongoing Z-1956-2021
The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the devices air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals.
-
- Terminated Z-1065-2016
Software Issue
-
- Terminated Z-1143-2014
Internal testing revealed a potentially defective component on the power management board that could affect the function of certain Trilogy Ventilators resulting in loss of therapy to patients.
-
- Terminated Z-2024-2012
The specified Trilogy units are being recalled because of the potential for a faulty component in the power supply.
Timeline
- Cleared FDA 510(k) K093416
- Recall initiated FDA recalls Z-2024-2012
- Recall initiated FDA recalls Z-1143-2014
- Recall initiated FDA recalls Z-1065-2016
- Listed FDA GUDID 00606959047419
- Recall initiated FDA recalls Z-1956-2021
- Recall initiated FDA recalls Z-0883-2023
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Trilogy 200
- Generic name
- Portable electric ventilator
- Model / Ref / Catalog
- Trilogy200 Ventilator, Korea (Philips), KO1032800
- Primary DI / UDI-DI
- 00606959047419
- 510(k) Number
- FDA product code
- DQA, CBK, NOU
- GMDN term
- Portable electric ventilator
- Device class
- Class II
- Regulation number
- 870.2700, 868.5895
- GUDID distribution status
- Not in Commercial Distribution
Similar devices
Other devices filed under FDA product code DQA (Oximeter).
- NT1D VITAL SIGNS MONITOR by New Tech, Inc.
- CONTEC CMS50DL1 by Contec Medical Systems Co., Ltd.
- Patient Monitor iM8B by Edan Instruments,Inc.
- Unimed Disposable and Reusable SPO2 Sensors by Unimed Medical Supplies, Inc.
- RAD-G 9895 by MASIMO CORPORATION
- NIHON KOHDEN OGS-2001A POCKETCARE AND ACCESSORIES by NIHON KOHDEN AMERICA, INC.
- Reusable SpO2 Sensor by SHENZHEN CHANGKE CONNECT ELECTRONICS CO., LTD.
- Radical-7™ Handheld signal extraction pulse co-oximeter™ 9183 by MASIMO CORPORATION
- CONTEC CMS50E by Contec Medical Systems Co., Ltd.
- Pulse Oximeter by Beijing Safe Heart Technology, Ltd.