  "format": "devicerts.device.v1",
  "cite_as": "Trilogy® 6200-80-20, Zimmer, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/trilogy-r-00-6200-080-20 (data as of 2026-11-26).",
  "source": {
    "canonical_url": "https://devicerts.com/devices/trilogy-r-00-6200-080-20",
    "json_url": "https://devicerts.com/devices/trilogy-r-00-6200-080-20.json",
    "markdown_url": "https://devicerts.com/devices/trilogy-r-00-6200-080-20.md",
    "publisher": "deviCERTS (devicerts.com)",
    "data_sources": [
      {
        "registry": "FDA GUDID (AccessGUDID)",
        "url": "https://accessgudid.nlm.nih.gov/"
      },
      {
        "registry": "EUDAMED",
        "url": "https://ec.europa.eu/tools/eudamed"
      },
      {
        "registry": "FDA recalls",
        "url": "https://open.fda.gov/apis/device/recall/"
      }
    ],
    "registry_records_last_synced": "2026-11-07",
    "status_as_of": "2026-11-26",
    "license": "CC BY 4.0",
    "license_url": "https://creativecommons.org/licenses/by/4.0/",
    "license_scope": "The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.",
    "attribution": "DevicErts, https://devicerts.com/devices/trilogy-r-00-6200-080-20",
    "disclaimer": "Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails."
  },
  "device": {
    "name": "Trilogy® 6200-80-20",
    "registry_name": "Trilogy® 6200-80-20",
    "url": "https://devicerts.com/devices/trilogy-r-00-6200-080-20",
    "manufacturer": {
      "name": "Zimmer, Inc.",
      "url": "https://devicerts.com/manufacturers/zimmer-inc",
      "country": "United States",
      "country_basis": null,
      "fda_registration_country": null
    },
    "status": {
      "state": "active",
      "label": "Active",
      "detail": "European Union and United States"
    },
    "classification": [
      {
        "class": "Class III",
        "system": "EU MDD"
      },
      {
        "class": "Class II",
        "system": "US FDA"
      }
    ],
    "identifiers": [
      {
        "label": "Catalogue number",
        "values": [
          {
            "value": "00-6200-080-20",
            "registries": [
              "FDA GUDID (AccessGUDID)"
            ]
          }
        ]
      },
      {
        "label": "Primary DI / UDI-DI",
        "values": [
          {
            "value": "00889024118416",
            "registries": [
              "EUDAMED",
              "FDA GUDID (AccessGUDID)"
            ]
          }
        ]
      },
      {
        "label": "Basic UDI-DI",
        "values": [
          {
            "value": "B-00889024118416",
            "registries": [
              "EUDAMED"
            ]
          }
        ]
      },
      {
        "label": "510(k) Number",
        "values": [
          {
            "value": "K934765",
            "registries": [
              "FDA GUDID (AccessGUDID)"
            ]
          }
        ]
      }
    ],
    "product_codes": [
      "LPH"
    ],
    "emdn": [
      {
        "code": "P090803010201",
        "term": "PRIMARY IMPLANT UNCEMENTED METAL ACETABULAR CUPS"
      }
    ],
    "gmdn": [
      {
        "code": "43167",
        "term": "Acetabular shell"
      }
    ],
    "description": null,
    "noindex": false
  },
  "authorizations": [
    {
      "registry": "EUDAMED",
      "region": "European Union",
      "type": "CE/MDD",
      "number": "B-00889024118416",
      "number_label": "Basic UDI-DI",
      "device_udi_di": "00889024118416",
      "date": "2026-11-02",
      "date_kind": "registered",
      "decision_code": null,
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": false
    },
    {
      "registry": "GUDID",
      "region": "United States",
      "type": "GUDID listing",
      "number": "00889024118416",
      "number_label": "UDI-DI",
      "device_udi_di": null,
      "date": "2015-09-24",
      "date_kind": "listed",
      "decision_code": null,
      "expires": null,
      "withdrawn": null,
      "status": "Listed",
      "status_note": "GUDID: in commercial distribution",
      "derived_from_gudid": false
    },
    {
      "registry": "GUDID",
      "region": "United States",
      "type": "FDA 510(k)",
      "number": "K934765",
      "number_label": null,
      "device_udi_di": null,
      "date": "1994-04-29",
      "date_kind": "issued",
      "decision_code": null,
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": true
    }
  ],
  "no_longer_listed_by": [],
  "certificates": [],
  "recalls": [
    {
      "number": "Z-1684-2016",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2016-05-04",
      "reason": "A small hole may be present in the inner tray of specific lots of sterile Hip and Trauma Implant Screws.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-1115-2016",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2016-01-11",
      "reason": "As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013.  The affected products are sterile.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-1123-2016",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2016-01-11",
      "reason": "As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013.  The affected products are sterile.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-1145-2016",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2016-01-11",
      "reason": "As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013.  The affected products are sterile.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-1161-2016",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2016-01-11",
      "reason": "As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013.  The affected products are sterile.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-0875-2015",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2014-12-04",
      "reason": "Zimmer received a single complaint wherein a Trilogy® Fiber Metal Multi-Hole Acetabular Shell would not attach to the inserter/impactor instrumentation. Subsequent investigation found the polar-hole threads to be present but non-conforming to specifications, in that the minor diameter\nwas undersized. Investigation also indicates that the issue is isolated and affects only lot 62714305, which",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-0824-2015",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2014-11-21",
      "reason": "Analysis of returned complaint devices, product in inventory, and device manufacturing records has identified tool marks isolated to one specific machining mill to be the cause of the fractures.  .",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-2032-2014",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2014-06-12",
      "reason": "Two lots of screws were commingled.  Screws with etching and machining for lot number 62629432 were packaged in bags labeled for lot number 62628759; and screws with etching and machining for lot number 62628759 were packaged in bags labeled for lot number 62629432.  The affected product was distributed between 3/6/14 and 4/21/14.",
      "applies": "shared submission",
      "via": "K934765"
    },
    {
      "number": "Z-1024-2014",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2013-10-11",
      "reason": "Zimmer recently conducted a review of all historic packaging validations at its Zimmer Manufacturing B.V. (ZMBV) facility in Ponce, Puerto Rico. Based on this review, it was determined that the packaging operations conducted in the Building 1 packaging operation at this facility were not properly validated. As a result, Zimmer conducted seal integrity testing to evaluate if previously packaged product from this facility met the established requirements for sterile barrier integrity. The acceptance criteria established for this testing was 99% reliability with a 90% confidence interval. These packaging tray configurations met the acceptance criteria for sterile barrier integrity of both the inner and outer trays, however, Zimmer has decided to recall all manufacturing lots that have not expired and that were sterile packaged in the ZMBV facility Building 1 packaging operations.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-0769-2013",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2012-09-14",
      "reason": "Some units of Trilogy shells manufactured since March 2009 may be below the lower range of the pore size specification (as low as 28% vs. 30% porosity specification). On 10/31/2012, the firm expanded the recall action to include lots of Uni-Hole Trilogy Acetabular System shells.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-0771-2013",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2012-09-14",
      "reason": "Some units of Trilogy shells manufactured since March 2009 may be below the lower range of the pore size specification (as low as 28% vs. 30% porosity specification). On 10/31/2012, the firm expanded the recall action to include lots of Uni-Hole Trilogy Acetabular System shells.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-0772-2013",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2012-09-14",
      "reason": "Some units of Trilogy shells manufactured since March 2009 may be below the lower range of the pore size specification (as low as 28% vs. 30% porosity specification). On 10/31/2012, the firm expanded the recall action to include lots of Uni-Hole Trilogy Acetabular System shells.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-0773-2013",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2012-09-14",
      "reason": "Some units of Trilogy shells manufactured since March 2009 may be below the lower range of the pore size specification (as low as 28% vs. 30% porosity specification). On 10/31/2012, the firm expanded the recall action to include lots of Uni-Hole Trilogy Acetabular System shells.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-0775-2013",
      "classification": "Class II",
      "status": "terminated",
      "initiated": "2012-09-14",
      "reason": "Some units of Trilogy shells manufactured since March 2009 may be below the lower range of the pore size specification (as low as 28% vs. 30% porosity specification). On 10/31/2012, the firm expanded the recall action to include lots of Uni-Hole Trilogy Acetabular System shells.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-0620-2008",
      "classification": "",
      "status": "terminated",
      "initiated": "2007-10-19",
      "reason": "Parts missing and incomplete etch:  The units may not contain the locking ring or the etched alignment marks on the rim.",
      "applies": "this device",
      "via": "K934765"
    },
    {
      "number": "Z-1344-06",
      "classification": "",
      "status": "terminated",
      "initiated": "2006-06-26",
      "reason": "Lack of assurance of sterility, as the sterile barrier packaging may have been compromised.",
      "applies": "shared submission",
      "via": "K934765"
    }
  ],
  "eu_market_availability": null,
  "properties": [
    {
      "group": "Identity",
      "fields": [
        {
          "label": "Trade name",
          "values": [
            {
              "value": "Trilogy®",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Generic name",
          "values": [
            {
              "value": "Acetabular shell",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Device name",
          "values": [
            {
              "value": "HP Trilogy/TM Mod Trilogy Acetabular Implant Shells",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Model / Ref / Catalog",
          "values": [
            {
              "value": "00-6200-080-20",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            },
            {
              "value": "6200-80-20",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Identifiers",
      "fields": [
        {
          "label": "Primary DI / UDI-DI",
          "values": [
            {
              "value": "00889024118416",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Basic UDI-DI",
          "values": [
            {
              "value": "B-00889024118416",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "510(k) Number",
          "values": [
            {
              "value": "K934765",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "FDA product code",
          "values": [
            {
              "value": "LPH",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "EMDN code",
          "values": [
            {
              "value": "P090803010201",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "GMDN term",
          "values": [
            {
              "value": "Acetabular shell",
              "code": "43167",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Classification",
      "fields": [
        {
          "label": "Device class",
          "values": [
            {
              "value": "Class III",
              "registries": [
                "EUDAMED"
              ]
            },
            {
              "value": "Class II",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Regulation number",
          "values": [
            {
              "value": "888.3358",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "EU registration type",
          "values": [
            {
              "value": "Legacy device (under a directive)",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "EU market of registration",
          "values": [
            {
              "value": "Netherlands",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "GUDID distribution status",
          "values": [
            {
              "value": "In Commercial Distribution",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Dimensions & Sizes",
      "fields": [
        {
          "label": "Size",
          "values": [
            {
              "value": "Outer Diameter — 80 Millimeter",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Properties",
      "fields": [
        {
          "label": "Supplied sterile",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Single use",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Implantable",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Prescription use",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Lot / batch number",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Expiration date",
          "values": [
            {
              "value": "Yes",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Sterilise before use",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Reusable",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains latex",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED",
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Reprocessed single-use device",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction)",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Incorporates a substance derived from human blood or plasma",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains human tissues or cells",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains animal tissues or cells",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Contains endocrine-disrupting substances",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Administering medicine",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Measuring function",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Incorporates a medicinal substance",
          "values": [
            {
              "value": "No",
              "registries": [
                "EUDAMED"
              ]
            }
          ]
        },
        {
          "label": "Over-the-counter",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Convenience kit",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Combination product",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "HCT/P",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Premarket exempt",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Serial number",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        },
        {
          "label": "Manufacturing date",
          "values": [
            {
              "value": "No",
              "registries": [
                "FDA GUDID (AccessGUDID)"
              ]
            }
          ]
        }
      ]
    }
  ]
}