Trilogy® 6141-70-28
Trilogy 6141-70-28 is a non-constrained polyethylene acetabular liner (FDA Class II) made by Zimmer, Inc., cleared under FDA 510(k) K972774 on 5 May 1999 (1 earlier submission) and listed in FDA GUDID since 24 Sep 2015 (UDI-DI 00889024361683), active as of 22 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00889024361683 | Date24 Sep 2015 | StatusListed |
| United States | FDA 510(k)SESE | NumberK972774 | Date5 May 1999 | StatusActive |
Official records
- AccessGUDID record 00889024361683
- FDA 510(k) database K972774
- FDA 510(k) database K954698
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K972774 decided 5 May 1999 Active
- FDA GUDID UDI-DI 00889024361683 listed 24 Sep 2015 Listed
Recalls
-
- Terminated Z-1024-2014
Zimmer recently conducted a review of all historic packaging validations at its Zimmer Manufacturing B.V. (ZMBV) facility in Ponce, Puerto Rico. Based on this review, it was determined that the packaging operations conducted in the Building 1 packaging operation at this facility were not properly validated. As a result, Zimmer conducted seal integrity testing to evaluate if previously packaged product from this facility met the established requirements for sterile barrier integrity. The acceptance criteria established for this testing was 99% reliability with a 90% confidence interval. These packaging tray configurations met the acceptance criteria for sterile barrier integrity of both the inner and outer trays, however, Zimmer has decided to recall all manufacturing lots that have not expired and that were sterile packaged in the ZMBV facility Building 1 packaging operations.
Timeline
- Cleared FDA 510(k) K954698
- Cleared FDA 510(k) K972774
- Recall initiated FDA recalls Z-1024-2014
- Listed FDA GUDID 00889024361683
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Trilogy®
- Generic name
- Non-constrained polyethylene acetabular liner
- Model / reference
- 6141-70-28
- Primary DI / UDI-DI
- 00889024361683
- FDA product code
- MLR, LPH
- GMDN term
- Non-constrained polyethylene acetabular liner
- Device class
- Class II
- Regulation number
- 880.6860, 888.3358
- GUDID distribution status
- In Commercial Distribution
- Size
- Lumen/Inner Diameter — 28 Millimeter
Similar devices in this category
Other devices filed under Non-constrained polyethylene acetabular liner.
- U2 Acetabular Components 1403-1756 by UNITED ORTHOPEDIC CORP.
- MobiliT Cup HDM2864 by CORIN LTD
- United Hip System 1406-3058 by UNITED ORTHOPEDIC CORP.
- Trinity Acetabular Hip System with HXLPE Liners 321.04.740 by CORIN LTD
- CSF Plus CLP75® Highly Cross Linked UHMWPE Liner 10° Hooded 28mm I/D for 60mm O/D Cup 151-60-28 by JRI Orthopaedics Ltd
- Cross-Linked PE Insert Acetabular Insert 0884004 by ADLER ORTHO SPA
- Liner X-PE BO76.1772.000.00 by Lincotek Bologna S.r.l