Trinity Acetabular Hip System 921.103
by Corin Ltd
Ref 921.103Model Trinity Acetabular System Instrument Set
Trinity Acetabular Hip System 921.103 is an orthopaedic implant impactor (EU MDD Class IIa; FDA Class II) made by Corin Ltd, registered in EUDAMED on 14 Oct 2026 (Basic UDI-DI B-05055196926943), cleared under FDA 510(k) K093472 on 23 Nov 2010 and listed in FDA GUDID since 17 Aug 2016 (UDI-DI 05055196926943), active as of 24 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-05055196926943 05055196926943 | Date14 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number05055196926943 | Date17 Aug 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK093472 | Date23 Nov 2010 | StatusActive |
Official records
- EUDAMED public site B-05055196926943
- AccessGUDID record 05055196926943
- FDA 510(k) database K093472
From the FDA record
- Device description
- FLEXIBLE DRIVE
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-05055196926943 registered 14 Oct 2026 Active
- FDA 510(k) K093472 decided 23 Nov 2010 Active
- FDA GUDID UDI-DI 05055196926943 listed 17 Aug 2016 Listed
Recalls
-
- Terminated Z-2604-2021
The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices.
Timeline
- Cleared FDA 510(k) K093472
- Listed FDA GUDID 05055196926943
- Recall initiated FDA recalls Z-2604-2021
- Registered EUDAMED B-05055196926943
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Modular Drive Shaft (Flexible) EUDAMEDTrinity Acetabular Hip System GUDID
- Generic name
- Orthopaedic implant impactor, reusable
- Model / Ref / Catalog
- 921.103, Trinity Acetabular System Instrument Set
- Primary DI / UDI-DI
- 05055196926943
- Basic UDI-DI
- B-05055196926943
- 510(k) Number
- FDA product code
- MEH, LWJ, LZO
- EMDN code
- L0999 Orthopaedic and traumatological surgery instruments, reusable - other
- GMDN term
- Orthopaedic implant impactor, reusable
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 888.3353, 888.3360
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under ORTHOPAEDIC AND TRAUMATOLOGICAL SURGERY INSTRUMENTS, REUSABLE - OTHER.
- Neo Medical Pedicle Screw System SI-RS-00-14 by Neo Medical Inc.
- APEX Knee System KR-42205 by OMNIlife science, Inc.
- APEX Knee System KS-90090-IN by OMNIlife science, Inc.
- GAUTHIER BIOMEDICAL G170402 by Gauthier Biomedical, Inc.
- 234-500-225 by Stryker Corp.
- MicroFrance® MCEN35 by Integra Microfrance
- MicroFrance® M823C by Integra Microfrance
- Cable-Ready® 2232-03-02 00-2232-003-02 by Zimmer, Inc.
- Gimmi KV.0250.15 by Gimmi GmbH